I/o terminal blocks, Wiring the main control board i/o terminals – Rockwell Automation 20D PowerFlex 700H and 700S Frame 9...14 Drives User Manual
Page 48

48
Rockwell Automation Publication PFLEX-IN006E-EN-P - July 2013
Chapter 3
Control Wiring for PowerFlex 700S Drives with Phase II Control
I/O Terminal Blocks
Wiring the Main Control Board I/O Terminals
Terminal blocks TB1 and TB2 contain connection points for all inputs, outputs
and standard encoder connections. Both terminal blocks reside on the main
control board in the control cassette. See
Figure 8
below for locations.
Table 17
and
Table 18
on page
49
contain detailed descriptions for the terminals
on TB1 and TB2. Remove the terminal block plug from the socket and make the
appropriate connections. See Removing the Control Cassette on page
instructions on removing the control cassette from the drive.
Reinstall the plug when wiring is complete. The terminal blocks have keys, which
make it difficult to insert a terminal plug into the wrong socket.
Table 16 - Control & Encoder Terminal Block Specifications
Figure 8 - Main Control Board I/O Terminal Block Locations
IMPORTANT
For NEMA/UL Type 1 applications, all wiring must be routed through the
conduit plate on the drive. Route any wires from the expanded cassette to the
base cassette and out of the drive.
Name
Description
Wires Size Range
(1)
(1) Maximum/minimum sizes the terminal block will accept - these are not recommendations.
Torque
Maximum
Minimum
Maximum
Recommended
I/O Terminal Blocks
Signal & Encoder power
connections
1.5 mm
2
(16 AWG)
0.14 mm
2
(28 AWG)
0.25 N
•
m
(2.2 lb
•
in)
0.22 N
•
m
(1.9 lb
•i
n)
TB1 Terminals
TB2 Terminals
Control