Table 8 – Rockwell Automation 20D PowerFlex 700H and 700S Frame 9...14 Drives User Manual
Page 174

174
Rockwell Automation Publication PFLEX-IN006E-EN-P - July 2013
Appendix A
Specifications
Table 8 - 932 Volt DC Input Frames 9…14 Drive Ratings
Drive Catalog
Number
Fram
e
kW Rating
PWM
Freq.
Temp.
DC Input
Ratings
Output Amps
ND
HD
kHz
°
C
Amps
Cont.
1 Min.
3 Sec.
20xM170
9
160
–
2
40
200
170
187
245
–
132
2
40
170
144
216
245
20xM208
9
200
–
2
35
245
208
230
289
–
160
2
40
200
170
250
289
20xM261
10 250
–
2
40
307
261
287
375
–
200
2
40
245
208
312
375
20xM325
10 315
–
2
40
383
325
358
470
–
250
2
40
307
261
392
470
20xM385
10 355
–
2
40
453
385
424
585
–
315
2
40
383
325
488
585
20xM416
10 400
–
2
35
490
416
458
585
–
315
2
40
383
325
488
585
20xM460
11 450
–
2
40
542
460
506
693
–
355
2
40
453
385
578
693
20xM502
11 500
–
2
40
591
502
552
828
–
400
2
40
542
460
690
828
20xM590
11 560
–
2
35
695
590
649
885
–
500
2
35
591
502
753
904
20xM650
12 630
–
2
40
765
650
715
1062
–
560
2
40
695
590
885
1062
20xM750
12 710
–
2
40
883
750
825
1170
–
630
2
40
765
650
975
1170
20xM820
(1)
(1) 20DM820 drives (ND) are only capable of producing 95% of starting torque under 10 Hz.
12 800
–
2
35
965
820
902
1170
–
630
2
35
765
650
975
1170
20xM920
13 900
–
2
40
1038
920
1012
1380
–
800
2
40
925
820
1230
1410
20xM1K0
13 1000
–
2
40
1162
1030
1133
1545
–
900
2
40
1038
920
1380
1755
20xM1K1
13 1100
–
2
35
1331
1180
1298
1755
–
1000
2
35
1162
1030
1463
1755
20xM1K5
14 1500
–
2
40
1766
1500
1650
2250
–
1300
2
40
1530
1300
1950
2340
20xM1K9
(2)
(2) Not available with 700S Control.
14 1800
–
2
40
2237
1900
2090
2700
–
1500
2
40
1766
1500
2250
2700
20xM2K2
(2)
14 2000
–
2
30
2649
2250
2475
3335
–
1800
2
30
2237
1900
2782
3335