Table 9 – Rockwell Automation 20D PowerFlex 700H and 700S Frame 9...14 Drives User Manual
Page 176
176
Rockwell Automation Publication PFLEX-IN006E-EN-P - July 2013
Appendix A
Specifications
Table 9 - 400 Volt AC Input Frames 9…14 Drive Protection Devices
Drive Catalog
Number
Fram
e
kW Rating
Input
Ratings
Dual Element Time Delay Fuse
Non-Time Delay Fuse
Bussmann Style Semi-
Conductor Fuse
Circuit
Breaker
(5)
Motor Circuit
Protector
(7)
ND
HD
Amps
Min.
(2)
Max.
(3)
Min.
(2)
Max.
(3)
Max.
(6)
Max.
20xC261
9
132
-
263
350
550
350
700
170M5813
700
400
-
110
207
275
450
275
600
170M5813
600
300
20xC300
9
160
-
302
400
650
400
900
170M5813
900
400
-
132
247
350
500
350
700
170M5813
700
400
20xC385
10 200
-
388
500
850
500
1100
170M5813
1100
600
-
160
302
400
650
400
900
170M5813
900
400
20xC460
10 250
-
463
600
1000
600
1300
170M8547
1300
600
-
200
388
500
850
500
1100
170M8547
1100
600
20xC500
10 250
-
504
650
1100
650
1500
170M8547
1500
700
-
250
423
550
900
550
1200
170M8547
1200
600
20xC590
11 315
-
594
750 (1 per phs)
375 (2 per phs)
1300
750 (1 per phs)
375 (2 per phs)
1700
170M5813
1700
800
-
250
524
700 (1 per phs)
350 (2 per phs)
1100
700 (1 per phs)
350 (2 per phs)
1500
170M5813
1500
700
20xC650
11 355
-
655
850 (1 per phs)
425 (2 per phs)
1400
850 (1 per phs)
425 (2 per phs)
1900
170M5813
1900
1000
-
315
594
750 (1 per phs)
375 (2 per phs)
1300
750 (1 per phs)
375 (2 per phs)
1700
170M5813
1700
800
20xC730
11 400
-
735
1000 (1 per phs)
500 (2 per phs)
1600
1000 (1 per phs)
500 (2 per phs)
2100
170M5813
2100
1200
-
355
655
850 (1 per phs)
425 (2 per phs)
1400
850 (1 per phs)
425 (2 per phs)
1900
170M5813
1900
1000
20xC820
12 450
-
826
1100 (1 per phs)
550 (2 per phs)
1800
1100 (1 per phs)
550 (2 per phs)
2400
170M8547
2400
1200
-
400
735
1000 (1 per phs)
500 (2 per phs)
1600
1000 (1 per phs)
500 (2 per phs)
2100
170M8547
2100
1200
20xC920
12 500
-
927
1200 (1 per phs)
600 (2 per phs)
2000
1200 (1 per phs)
600 (2 per phs)
2700
170M8547
2700
1200
-
450
826
1100 (1 per phs)
550 (2 per phs)
1800
1100 (1 per phs)
550 (2 per phs)
2400
170M8547
2400
1200
20xC1K0
12 560
-
1038
1350 (1 per phs)
700 (2 per phs)
2300
1350 (1 per phs)
700 (2 per phs)
3000
170M8547
3000
1400
-
500
927
1200 (1 per phs)
600 (2 per phs)
2000
1200 (1 per phs)
600 (2 per phs)
2700
170M8547
2700
1200
20xC1K1
13 630
-
1158
1350 (1 per phs)
700 (2 per phs)
2300
1350 (1 per phs)
700 (2 per phs)
3000
170M6466
(4)
3000
1400
-
560
1038
1500 (1 per phs)
750 (2 per phs)
2500
1500 (1 per phs)
750 (2 per phs)
3400
170M6466
(4)
3400
1500
20xC1K3
13 710
-
1310
1700 (1 per phs)
850 (2 per phs)
2900
1700 (1 per phs)
850 (2 per phs)
3900
170M6466
(4)
3900
1700
-
630
1158
1500 (1 per phs)
750 (2 per phs)
2500
1500 (1 per phs)
750 (2 per phs)
3400
170M6466
(4)
3400
1500
20xC1K4
13 800
-
1461
1900 (1 per phs)
950 (2 per phs)
3000
1900 (1 per phs)
950 (2 per phs)
4300
170M6466
(4)
4300
1900
-
710
1209
1600 (1 per phs)
800 (2 per phs)
2700
1600 (1 per phs)
800 (2 per phs)
3600
170M6466
(4)
3600
1600
20xC1K7
(1)
14 1000
-
1783
2500 (1 per phs)
825 (3 per phs)
3900
2500 (1 per phs)
825 (3 per phs)
5300
170M6466
5300
2500
-
900
1612
2100 (1 per phs)
700 (3 per phs)
3500
2100 (1 per phs)
700 (3 per phs)
4800
170M6466
4800
2100
20xC2K1
(1)
14 1200
-
2166
3000 (1 per phs)
1000 (3 per phs)
4800
3000 (1 per phs)
1000 (3 per phs)
6400
170M6466
6400
3000
-
1100
1954
2500 (1 per phs)
825 (3 per phs)
4300
2500 (1 per phs)
825 (3 per phs)
5800
170M6466
5800
2500
20xC2K7
(1)
14 1600
-
2720
3500 (1 per phs)
1200 (3 per phs)
6000
3500 (1 per phs)
1200 (3 per phs)
8000
170M6466
8000
3500
-
1300
2317
3000 (1 per phs)
1000 (3 per phs)
5000
3000 (1 per phs)
1000 (3 per phs)
6900
170M6466
6900
3000
(1) Not available with 700S Control.
(2) Minimum protection device size is the lowest rated device that supplies maximum protection without nuisance tripping.
(3) Maximum protection device size is the highest rated device that supplies drive protection.
(4) These fuses and disconnect are supplied with AC input NEMA/UL Type 1 drives.