APPENDIX G

49’1340 e

FlexPak 3000

G-7

Table G.1 - User Quick Reference Table for Input Parameters

(continued)

Par.

Parameter

Parameter Selection /

Pg Initial Factory

User Data

No.

Adjustment

Range

B-

Setting

Date

Setting

Level Detectors

602

LEVEL DETECT 1 SELECT

• SPD SOURCE SELECT OUT

• SPEED RAMP INPUT TP

• SPEED RAMP OUTPUT

• SPD LOOP FEEDBACK

• CML FEEDBACK

24

SPD LOOP

FEEDBACK

603

LEVEL DETECT 1 THRESH

• 0.1 to 100.0% if LEVEL

DETECT 1 SELECT is not set
to CML FEEDBACK

• 0.1 to MAXIMUM CURRENT%

if LEVEL DETECT 1 SELECT
is set to CML FEEDBACK

24

10.0%

604

LEVEL DETECT 1 DELAY

0.0 - 300.0 sec

24

10.0 sec

605

LEVEL DETECT 2 SELECT

• SPD SOURCE SELECT OUT

• SPEED RAMP INPUT TP

• SPEED RAMP OUTPUT

• SPD LOOP FEEDBACK

• CML FEEDBACK

25 SPEED RAMP

INPUT TP

606

LEVEL DETECT 2 THRESH

• 0.1 - 100.0% if LEVEL

DETECT 2 SELECT is not set
to CML FEEDBACK

• 0.1 to MAXIMUM CURRENT%

if LEVEL DETECT 2 SELECT
is set to CML FEEDBACK

25

10.0%

607

LEVEL DETECT 2 DELAY

0.0 - 300.0 sec

24

10.0 sec

608

TACH LOSS SCR ANGLE

0 to 127 (degrees)

50 109

609

PHASE LOSS DETECT EN

DISABLE,

ENABLE

42 ENABLE

Outer Current Loop

800

OCL REFERENCE SELECT

• REGISTER

• ANALOG IN 1

• ANALOG IN 2

• FREQUENCY IN

• NETW IN REG 1

• NETW IN REG 2

• NETW IN REG 3

40

REGISTER

801

OCL REF REGISTER

-4095 - 4095

40

0

802

OCL REF RAMP TIME

0.0 - 300.0 sec

39

10.0 sec

803

OCL REF ROUNDING

0 - 50%

40

0%

804

OCL FEEDBACK SELECT

• NONE

• CML FEEDBACK

• ANALOG IN 1

• ANALOG IN 2

• 5=SPEED LOOP OUTPUT

• 6=ANALOG AUTO REF

• 7= NETW IN REG 1

• 8= NETW IN REG 2

• 9= NETW IN REG 3

37

CML

FEEDBACK

805

OCL LEADLAG SELECT

• LEAD/LAG

• BYPASS

• LAG/LEAD

38

BYPASS

806

OCL LEADLAG LOW FREQ

0.01 - 34.90 rad/s

37

1.00 rad/s

807

OCL LEADLAG RATIO

2 - 20

37

10