beautypg.com

Rockwell Automation FlexPak 3000 Power Module SW-Version 4.3 User Manual

Page 101

background image

REPLACEMENT PARTS and ACCESSORIES

49’1340 e

FlexPak 3000

8-21

Radio Interference Filter 600 ,1000 and 1600 A, 500/690 V

L3 L2 L1

LINE

PE L1/L3 L2

C

D

G

E

LOAD

L3' L2' L1'

PE' L1'/L3' L2'

H

Q

M

S

T

P

L

K

=

=

A

B

F

R

I

[A]

Filter
Part No.

A

B

C

D

E

F

G

H

K

L

M

600 839.73-92 590 500 250 154 280 280 305 150 94.5 61.5 26

1000 839.73-95 610 500 250 198 280 280 305 172 90 51 26

1600 839.73-98 844 650 400 210 440 320 465 192 92 56 28

I

[A]

P

Q

R

S

T

Ground

Bolt

W

[kg]

P

v

[W]

600

15 30 30

11

12

M10 49

45

1000 20 40 30

11

12

M10 65

120

1600 20 40 40

2x

14

12

M12 180

220

Figure 8-12

600, 1000 and 1600 A, 500/690 V RFI-Filter Dimensions (mm)