REPLACEMENT PARTS and ACCESSORIES

FlexPak 3000 49’1340

e

8-20

Radio Interference Filter 250, 500, 1000 and 1600 A, 440 V

L3 L2 L1

LINE

PE L1/L3 L2

C

D

G

E

LOAD

L3' L2' L1'

PE' L1'/L3' L2'

H

Q

M

S

T

P

L

K

=

=

A

B

F

R

I

[A]

Filter
Part No.

A

B

C

D

E

F

G

H

K

L

M

250 839.73-25 460 350 230 149 260 200 285 120 100 79.5 24

500 839.73-31 590 500 250 154 280 280 305 150 93 59.5 24

1000 839.73-35 840 650 400 204 440 320 465 262 127 79 34

1600 839.73-38 870 680 400 204 440 340 465 262 127 79 34

I

[A]

P

Q

R

S

T

Ground

Bolt

W

[kg]

P

v

[W]

250

- 24 30

10.5

10.5

M10 18

18

500

15 30 30

11

12

M12 49

45

1000 20 50 40

14

12

M12 90

90

1600 20 50 40

2x

14

12

M12 130

144

Figure 8-11

250, 500, 1000 and 1600 A, 440 V RFI-Filter Dimensions (mm)