13 parameter reference – Lenze c300 User Manual
Page 182
![background image](/manuals/566291/182/background.png)
Lenze · Controller | Parameter setting & programming · Reference Manual · DMS 1.5 EN · 04/2014 · TD17
182
13
Parameter reference
13.9
Communication cards: optional interface
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C1093
C1094
C1096
C1098
Parameters of the second CAN interface
C1113
Parameter | Name:
C1093 | Error counter
Data type: UNSIGNED_32
Index: 23482
d
= 5BBA
h
Error counter since last initialisation of the CAN interface
Display range
(min. value | unit | max. value)
Read access Write access CINH PLC-STOP No transfer
Parameter | Name:
C1094 | Last error code
Data type: UNSIGNED_32
Index: 23481
d
= 5BB9
h
Code of the last error that occurred
Display range
(min. value | unit | max. value)
Read access Write access CINH PLC-STOP No transfer
Parameter | Name:
C1096 | CAN node ID
Data type: UNSIGNED_8
Index: 23479
d
= 5BB7
h
Setting range
(min. value | unit | max. value)
Lenze setting
0
128 63
Read access Write access CINH PLC-STOP No transfer
Parameter | Name:
C1098 | Channel
Data type: UNSIGNED_32
Index: 23477
d
= 5BB5
h
Setting range
(min. value | unit | max. value)
Lenze setting
0
Read access Write access CINH PLC-STOP No transfer
Parameter | Name:
C1113 | Device: Driver index
Data type: UNSIGNED_32
Index: 23462
d
= 5BA6
h
Index of the device driver. Since there can be more than one CAN interface, several instances can be run via the
driver.
Display range
(min. value | unit | max. value)
Read access Write access CINH PLC-STOP No transfer