Parameter, C0048, 13 parameter reference – Lenze c300 User Manual
Page 134
![background image](/manuals/566291/134/background.png)
Lenze · Controller | Parameter setting & programming · Reference Manual · DMS 1.5 EN · 04/2014 · TD17
134
13
Parameter reference
13.2
Basic parameters of the Controllers 3200 C/c300 and p300/p500
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C0042
C0043
C0048
C0049
C0050
Parameter | Name:
C0042 | Number of reboots
Data type: UNSIGNED_32
Index: 24533
d
= 5FD5
h
Number of boot processes of the device
Display range
(min. value | unit | max. value)
0
65535
Read access Write access CINH PLC-STOP No transfer
Parameter | Name:
C0043 | Activate Explorer
Data type: UNSIGNED_8
Index: 24532
d
= 5FD4
h
Deactivate option to hide the WindowsCE user interface/task bar on the controller
• The VisiWin-Remote Access Manager remains visible.
Setting range
(min. value | unit | max. value)
Lenze setting
0
1 1
Read access Write access CINH PLC-STOP No transfer
Parameter | Name:
C0048 | Logbook: Time to auto persist
Data type: UNSIGNED_32
Index: 24527
d
= 5FCF
h
The time for the timer is entered in minutes. The timer is restarted when the log service has saved data. If the time
has expired and no logbook entries have been saved in the meantime, the saving process will be activated.
Setting range
(min. value | unit | max. value)
Lenze setting
min
2 min
Read access Write access CINH PLC-STOP No transfer
Parameter | Name:
C0049 | Entry count to auto persist
Data type: UNSIGNED_32
Index: 24526
d
= 5FCE
h
Enter the number of logbook entries after which the saving process is to be activated. Counting starts with the last
saving.
Setting range
(min. value | unit | max. value)
Lenze setting
0
150 150
Read access Write access CINH PLC-STOP No transfer
Parameter | Name:
C0050 | Logbook: Max. entries
Data type: UNSIGNED_32
Index: 24525
d
= 5FCD
h
Enter the maximum number of logbook entries. The logbook entries are taken from the main memory and from the
SD memory card.
Setting range
(min. value | unit | max. value)
Lenze setting
100
10000 3000
Read access Write access CINH PLC-STOP No transfer