13 parameter reference – Lenze c300 User Manual
Page 167
13
Parameter reference
13.5
EtherCAT
167
Lenze · Controller | Parameter setting & programming · Reference Manual · DMS 1.5 EN · 04/2014 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C286/12
C286/13
C286/14
Parameter | Name:
C286/12 | ECAT counter: acyclical frames
Data type: UNSIGNED_32
Index: 24289.12
d
=
0x5EE1.0x0C
h
Number of acyclical frames
Display range
(min. value | unit | max. value)
0
4294967295
Read access Write access CINH PLC-STOP No transfer
Parameter | Name:
C286/13 | ECAT counter: acyclical datagrams
Data type: UNSIGNED_32
Index: 24289.13
d
=
0x5EE1.0x0D
h
Number of acyclical datagrams
Display range
(min. value | unit | max. value)
0
4294967295
Read access Write access CINH PLC-STOP No transfer
Parameter | Name:
C286/14 | ECAT: Reset individual counters
Data type: UNSIGNED_32
Index: 24289.14
d
=
0x5EE1.0x0E
h
Reset frame and datagram counters (C1086/7 ... 13)
Selection list
(Lenze setting printed in bold)
0 No Operation
1 Reset - All counters
2 Reset - Tx frame counters
4 Reset - Rx frame counters
8 Reset - Lost frame counters
16 Clear Cyclical Frame Counter
32 Clear Cyclical Datagram Counter
64 Reset - Acyclic frame counters
128 Reset - Acyclic datagram counters
Read access Write access CINH PLC-STOP No transfer