Parameter reference
13.2
Basic parameters of the Controllers 3200 C/c300 and p300/p500
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C0056
C0057
C0058
C0064
C0070
Parameter | Name:
C0056 | Logbook: Index of last entry on CF
Data type: UNSIGNED_32
Index: 24519
d
= 5FC7
h
Number of the last entry on the SD memory card
Display range
(min. value | unit | max. value)
Read access Write access CINH PLC-STOP No transfer
Parameter | Name:
C0057 | Logbook: Index of last entry
Data type: UNSIGNED_32
Index: 24518
d
= 5FC6
h
Number of the last entry in the logbook
Display range
(min. value | unit | max. value)
Read access Write access CINH PLC-STOP No transfer
Parameter | Name:
C0058 | Logbook: Time of last entry
Data type: DATE
Index: 24517
d
= 5FC5
h
Time of the last entry in the logbook
Display range
(min. value | unit | max. value)
(Local time
Read access Write access CINH PLC-STOP No transfer
Parameter | Name:
C0064 | Logbook: Time of last error entry
Data type: DATE
Index: 24511
d
= 5FBF
h
Entry of the last time error in the logbook
Display range
(min. value | unit | max. value)
(Local time
Read access Write access CINH PLC-STOP No transfer
Parameter | Name:
C0070 | Ratio: Data/program memory
Data type: UNSIGNED_32
Index: 24505
d
= 5FB9
h
• A part of the available memory is provided to the current programs as main memory.
• The other part is available as object store for saving files in the RAM.
• The percentage value indicated shows the ratio between object store (MemoryVirtualFilesAll) and total memory.
Setting range
(min. value | unit | max. value)
Lenze setting
0
%
27 27 %
Read access Write access CINH PLC-STOP No transfer