12 visualisation with »visiwinnet – Lenze c300 User Manual
Page 105

12
Visualisation with »VisiWinNET®«
12.4
Use the Direct driver "LogicAndMotionV3" (local visualisation)
105
Lenze · Controller | Parameter setting & programming · Reference Manual · DMS 1.5 EN · 04/2014 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
12.4.3
Using the variables browser to access variables (browse variables)
The variables browser can be used to browse for variables on the devices connected to the controller
and to transfer them to a project subsequently. For this purpose, a connection between the
integrated »VisiWinNET®« development environment and the controller is not required. The data is
read from the locally available symbol description files, which have been exported from the »EASY
Starter« in advance.
How to call up the Variables Browser:
1. Open the VariablesChannels folder in the Project Explorer.
Alternatively, you can browse variables when creating a new project.
2. Execute the Browse variables command in the context menu of the intended
communication channel.
In the VisiWinNET Lenze Variables Browser dialog box, all available devices for reading
variable definitions can be seen in the Devices selection list.
»PLC Designer« Online help
More information about this topic can be found in the following section:
"Symbol configuration editor"