beautypg.com

8 current batch, 1 general information, Current batch – JUMO 705060 mTRON T - Multifunction Panel 840 Operating Manual User Manual

Page 67: 7 visualization

background image

67

7 Visualization

7.8

Current batch

7.8.1

General information

Using the multifunction panel, nine different batches (batch reports) can be recorded and reg-
istered in parallel. In the visualization, a distinction is made between a "current batch" and the
last "completed batch". The number of batch reports used and the text in the batch visualization
can be configured on the multifunction panel or using the setup program.

Batch start/batch end

If the batch start was selected using the touchpad, then the batch reporting is started and ended
by touching the button. If a different type of batch start has been selected, the button is inactive.

Batch texts, "left column"

The texts in the "left column" are predetermined by the configuration and cannot be changed
during batch reporting.

(1)

(3)

(4)

(6)

(7)

(8)

(5)

(2)

(1) Batch start/batch end

(2) Batch texts, "left column"

(3) Batch status

(4) Batch texts, "right column"

(5) Communication status

(6) Batch selection

(7) Batch rotation

(8) Home button

NOTE!
There must be at least 5 seconds between the end of a batch (batch end) and the next start
(batch start). A new batch can only be started once this period has elapsed.