13 Configuration

Parameter

Parameter

Selection/settings

Description

Daily

Daily specifies whether a report is to be run for a day (24 hours). The completion
and restart will be determined by the Synchronizat. time parameter.

Off, On

If "On", the daily report will be run.

Periodically

Periodically specifies whether a period report is to be run. The completion and
restart will be determined by the Period and Synchronizat. time parameters.

Off, On

If "On", the periodical report will be run.

Period

1 min to 12 h

Period is used as the report end and
restart for the periodical report.

Weekly

Weekly specifies whether a report is to be run for a week. The completion and
restart will be determined by the Weekday and Synchronizat. time parameters.

Off, On

If "On", the weekly report will be run.

Weekday

Sunday to Saturday

Weekday is used together with the Syn-
chronizat. time parameter as the report
end and restart for the weekly report.

External

External specifies whether an external report is to be run and also whether the
external signal (Ext. start) is set (High).

Off, On

If "On", the external report will be run.

Ext. start

Inactive

Digital selector

Ext. start specifies the start signal for the
external report.

Monthly

Monthly specifies whether a report is to be run for a month. The completion and
restart are performed on the first day of the month at 00:00.

Off, On

If "On", the monthly report will be run.

Yearly

Yearly specifies whether a report is to be run for a year. The completion and restart
are performed on the first day of the year at 00:00.

Off, On

If "On", the yearly report will be run.

Total

Total specifies whether a report is to be run for the total duration of the current con-
figuration of the multifunction panel.

Off, On

If "On", the total report will be run.

Synchronizat.
time

Synchronizat. time is used as the report end and restart for the daily, weekly, and
periodical report.

00:00:00

Time of synchronization

Out of range

This parameter decides what happens if an analog channel is outside of the valid
measuring range (scaling).

Stop

The reports for this channel are stopped.
If the measured values are within the
measuring range limits, these will be
restarted.

Delete

The reports are set to invalid ("-----") and
only restarted following the configured
report end.

?

?

?