2 Description

26

10s

10s

10s

10s

10s

10s

10s

10s

t

t1

t2

t3

t4

10s

t6

t5

t1 Saved via "Min. memory rate" (controlled save) and new tolerance band is set.

t2 Not saved, as the measured value at the end of the memory rate (10 s) is once again within the

tolerance.

t3 The new tolerance band is saved and set, as the measured value at the end of the memory rate

had left the tolerance band.

t4 The new tolerance band is saved and set, as the measured value at the end of the memory rate

had left the tolerance band.

t5 Saved via "Min. memory rate" (controlled save) and new tolerance band is set.

t6 Not saved, as the measured value at the end of the memory rate (10 s) is once again within the

tolerance.

NOTE!
It is not mandatory to register when the tolerance band has been exited. If the measured val-
ues return to the tolerance band within the memory rate (t2), no registration takes place; the
"Min. memory rate" is always active.