13 Configuration

Setup dialog

Parameter

Parameter

Selection/settings

Description

Memory status

On

The data is saved if this operating mode
is active.

Off

The data is not saved if this operating
mode is active.

Memory values

Average value

The average across the configured
memory rate is calculated and saved.

Current value

The current value is saved at the config-
ured memory rate.

Min. value

The minimum is saved at the configured
memory rate.

Max. value

The maximum is saved at the config-
ured memory rate.

Min./max. value

The minimum and the maximum (peak
value and envelope diagram) are saved
at the configured memory rate.

Eco operation

Using this method, a save operation is
performed if the measured value devi-
ates from the previous saved value by a
specific amount or if a digital channel
belonging to the group changes its sta-
tus.

?

?