Message ID
Message Text
Explanation
Updating System Scripts on page
.
KAPL13519-E
An HDLM file required for the
dlmupdatesysinit utility was not
found. File name = aa...aa
Details
aa...aa: File name
Action
Reinstall an HDLM.
KAPL13520-E
An HDLM directory required for
the dlmupdatesysinit utility was
not found. Directory name =
aa...aa
Details
aa...aa: Directory name
Action
Reinstall an HDLM.
KAPL13521-E
A command has failed.
Command = aa...aa, Details =
bb...bb
Details
aa...aa: Command that failed
bb...bb: Message that the
command output
Action
Remove the error cause described
in the message output by the
command indicated in the
message KAPL134521-E. Next, re-
execute the dlmupdatesysinit
Utility for Updating System Scripts
KAPL13522-E
The HDLM file is invalid. File
name = aa...aa
Details
A file necessary for processing
dlmupdatesysinit utility cannot be
found. Alternatively, the content
of a file is invalid.
aa...aa: Name of file where error
was detected.
Action
Reinstall an HDLM.
KAPL13601-W The audit log configuration file
does not exist. Restart the
HDLM Manager, and execute the
"dlnkmgr view -sys -audlog"
command and check the setting.
Details
The audit log configuration file
does not exist.
Action
Restart the HDLM manager,
execute the "dlnkmgr view -sys
-audlog" command, and then
specify any desired settings by
using the "dlnkmgr set -audlog"
command or the "dlnkmgr set -
audfac" command as necessary.
KAPL13602-W The audit log configuration file
cannot be opened. Execute the
"dlnkmgr view -sys -audlog"
Details
8-126
Messages
Hitachi Dynamic Link Manager User Guide (for Linux(R))