HP XP P9500 Storage User Manual
Page 529
Message ID
Message Text
Explanation
KAPL10005-W The number of parameters is
insufficient.
Details
The -f parameter exists but the
file for defining the information to
be collected does not exist. The
number of parameters is
insufficient.
Action
Check the parameters of the
DLMgetras utility for collecting
HDLM error information, and then
retry. For details on the
DLMgetras utility, see
Utility for Collecting HDLM Error
KAPL10006-W The file for defining the
information to be collected does
not exist, or cannot be read.
Value = aa...aa
Details
The file for defining the
information to be collected does
not exist, or the specified file
exists but the permission to read
the file is missing.
aa...aa: Name of the file for
defining the information to be
collected
Action
Check whether the specified file
for defining the information to be
collected exists, and check
whether you have access
permission for the specified file.
KAPL10007-W A directory has been specified in
the third parameter. Value =
aa...aa
Details
A directory is specified for the -f
parameter.
aa...aa: Third parameter
Action
Check the parameters of the
DLMgetras utility for collecting
HDLM error information, and then
retry. For details on the
DLMgetras utility, see
Utility for Collecting HDLM Error
KAPL10008-W You lack write permission for
the specified directory. Value =
aa...aa
Details
You do not have write permission
for the specified directory,
or the creation of a subdirectory
of the specified directory failed.
aa...aa: first parameter
Action
Check the following.
Messages
8-69
Hitachi Dynamic Link Manager User Guide (for Linux(R))