Message ID
Message Text
Explanation
Action
Check the parameters of the
DLMgetras utility for collecting
HDLM error information, and then
retry. For details on the
DLMgetras utility, see
Utility for Collecting HDLM Error
KAPL10002-W Too many parameters have
been specified.
Details
Four or more parameters have
been specified.
Action
Check the parameters of the
DLMgetras utility for collecting
HDLM error information, and then
retry. For details on the
DLMgetras utility, see
Utility for Collecting HDLM Error
KAPL10003-W The first parameter has not
been set to a directory. Value =
aa...aa
Details
A value which is not a directory
name is set for the first
parameter. The first parameter
must be a directory to which
collected information will be
output.
aa...aa: First parameter
Action
Check the parameters of the
DLMgetras utility for collecting
HDLM error information, and then
retry. For details on the
DLMgetras utility, see
Utility for Collecting HDLM Error
KAPL10004-W The parameter contains an
incorrect value. Value = aa...aa
Details
The first parameter must be a
directory. The second parameter
must be -f.
aa...aa: Invalid parameter
Action
Check the parameters of the
DLMgetras utility for collecting
HDLM error information, and then
retry. For details on the
DLMgetras utility, see
Utility for Collecting HDLM Error
8-68
Messages