Ldev -55 – HP XP P9500 Storage User Manual
Page 407
Displayed item
Description
No summary
displayed
Summary
displayed
•
A value of at least 0: Indicates the number
of errors that occurred during intermittent
error monitoring.
•
*: Indicates that an intermittent error
occurred (automatic failback does not check
the path).
HCTL
#1
-
SCSI device configuration information. The
following information is shown in "a.b.c.d"
format:
a: Host port number (hexadecimal number)
b: Bus number (hexadecimal number)
c: Target ID (hexadecimal number)
d: Host LU number (hexadecimal number)
-
Paths
Total number of the paths recognized by HDLM
for the LU to be displayed.
-
OnlinePaths
Number of available paths in the displayed
paths, indicated by a decimal number. When the
value of Paths equals the value of OnlinePaths,
all paths are online. If the value of OnlinePaths
is less than that of Paths, some paths are
offline. In this case, you should check the offline
paths and take appropriate action for any paths
that have an error status.
Legend:
- : Not displayed
#1
This information is displayed when one of the following conditions exist:
- The user selected the item to be displayed by using the -lu -item
parameter.
- all was specified.
- No value was specified for the parameter.
#2
This information is displayed when one of the following conditions exist:
- The user selected the item to be displayed by using the -lu -c -item
parameter.
- No value was specified for the parameter.
To display corresponding information about an HDLM device, SCSI device, and
LDEV
-drv
Command Reference
6-55
Hitachi Dynamic Link Manager User Guide (for Linux(R))