HP Storage Mirroring Software User Manual
Page 475
![background image](/manuals/398360/475/background.png)
473 of 739
ID
Category
Severity
Event Message
Required Response
node interval specified
for the resource.
10001 GeoCluster
Info.
Reconnect succeeded to
node %1 for resource %2.
Will be added as a possible
owner when mirror is
complete.
No action required.
10002 GeoCluster
Error
Disk check failed on node
%1 for resource %2.
Removing as a possible
owner.
Ensure that GeoCluster
is running on all possible
owners and that it can
communicate on the
public network. Also
ensure that the disk
specified for the resource
is functioning correctly
on all possible owners.
10003 GeoCluster
Error
Owner %1 of the quorum
resource %2 couldn't
access the arbitration path
%3. Network may be down.
Ensure that the network
used to access the
arbitration path is up and
that the server is
operational. Also ensure
that the arbitration share
path does exist and that
the account running the
cluster service has write
privileges to the share
path.
10004 GeoCluster
Warning
Failover of the group %1 is
being delayed. Group will
be brought online when the
target queue is below the
limit or the timeout has
expired.
No action required.
10005 GeoCluster
Info.
Node %1 is taking
ownership of the group %2.
The group will be brought
online on this node.
No action required.
- StorageWorks MSL6000 Tape Library (61 pages)
- Лент-е накопители HP StoreEver DAT (64 pages)
- Лент-е накопители HP StoreEver DAT (50 pages)
- StoreEver Ultrium Tape Drives (61 pages)
- StoreEver TapeAssure Software (40 pages)
- StoreEver Ultrium Tape Drives (75 pages)
- StoreEver Ultrium Tape Drives (60 pages)
- Linear Tape File System Software (28 pages)
- Linear Tape File System Software (25 pages)
- StoreEver Ultrium Tape Drives (78 pages)
- StoreEver Ultrium Tape Drives (76 pages)
- Linear Tape File System Software (20 pages)
- 2600fx Optical Disk Drive (65 pages)
- Ленточный автозагрузчик HP StorageWorks DAT 72x10 (58 pages)
- StorageWorks 1500cs Modular Smart Array (52 pages)
- StorageWorks 1500cs Modular Smart Array (71 pages)
- 2000fc Modular Smart Array (150 pages)
- StorageWorks 1000 Modular Smart Array (72 pages)
- StorageWorks 1000 Modular Smart Array (81 pages)
- StorageWorks 1500cs Modular Smart Array (48 pages)
- Servidor de almacenamiento HP ProLiant DL585 G2 (152 pages)
- Sistemas de almacenamiento de red HP StorageWorks X3000 (152 pages)
- Software de HP StoreVirtual VSA (127 pages)
- Software de HP StoreVirtual VSA (85 pages)
- X500 Data Vault (331 pages)
- StorageWorks 1000i Virtual Library System (122 pages)
- StorageWorks XP Remote Web Console Software (20 pages)
- 200 Storage Virtualization System (176 pages)
- XP Array Manager Software (101 pages)
- StorageWorks MSA 2.8 SAN Switch (307 pages)
- StorageWorks MSA 2.8 SAN Switch (22 pages)
- StorageWorks MSA 2.8 SAN Switch (104 pages)
- StorageWorks MSA 2.8 SAN Switch (270 pages)
- StorageWorks All-in-One SB600c Storage Blade (72 pages)
- StorageWorks All-in-One SB600c Storage Blade (80 pages)
- StorageWorks All-in-One SB600c Storage Blade (78 pages)
- StorageWorks All-in-One SB600c Storage Blade (60 pages)
- ProLiant DL585 G2 Storage-Server (150 pages)
- Data Protector Express Basic-Software (83 pages)
- Data Protector Express Basic-Software (93 pages)
- ProLiant DL185 G5 Storage Server (174 pages)
- ProLiant High Availability Storage Server (72 pages)
- 2000I G2-Modular-Smart-Array (48 pages)
- P2000 G3 MSA Array Systems (58 pages)
- StorageWorks 2000fc G2 Modular Smart Array (76 pages)