Calculate:marker:peak:data, Calculate:marker:peak:excursion, Calculate:marker:peak:sort:type – GW Instek GSP-930 Programming Manual User Manual
Page 85

REMOTE CONTROL
83
:CALCulate:MARKer:PEAK:DATA?
Query
Description
Returns all the top 10 peak data values in CSV
format (returns the contents of the peak table).
The
the top 10 peaks. Each pair includes the peak
frequency and the peak amplitude. There are a
total of 10 pairs of data points (20 data entries in
total) for the
Query syntax
:CALCulate:MARKer:PEAK:DATA?
Return parameter
pk#1 freq, pk#1 amp,….. pk#10 freq,
pk#10 amp.
Example
:CALCulate:MARKer:PEAK:DATA?
>1.250e+08,-5.052e+01,1.065000000e+09,…
:CALCulate:MARKer:PEAK:EXCursion
Set
Query
Description
Sets or queries the peak excursion value.
Syntax
:CALCulate:MARKer:PEAK:EXCursion
Query Syntax
:CALCulate:MARKer:PEAK:EXCursion?
Parameter
Peak excursion dB (offset from
threshold)
Return parameter
Peak excursion in dB.
Example
:CALC:MARK:PEAK:EXC 6 db
:CALCulate:MARKer:PEAK:SORT:TYPE
Set
Query
Description
Sets or queries the peak sort type for the peak
table.
Syntax
:CALCulate:MARKer:PEAK:SORT:TYPE
{FREQuency|AMPLitude}
Query Syntax
:CALCulate:MARKer:PEAK:SORT:TYPE?