beautypg.com

Calculate:jitter:phase, Calculate:jitter:time, Calculate:limit:clear – GW Instek GSP-930 Programming Manual User Manual

Page 78: Calculate:limit:data

background image

GSP-930 Programming Manual

76

:CALCulate:JITTer:PHASe?

Query

Description

Returns the carrier phase jitter in radians.

Query Syntax

:CALCulate:JITTer:PHASe?

Return parameter

Rad

Query Example

:CALC:JITT:PHAS?
>1.5307e+01

:CALCulate:JITTer:TIME?

Query

Description

Returns the carrier jitter time in seconds.

Query Syntax

:CALCulate:JITTer:TIME?

Return parameter

Seconds

Query Example

:CALC:JITT:TIME?
>.5.31e-08

:CALCulate:LIMit:CLEar

Set

Description

Clears the High Limit, Low Limit and the
Pass/Fail state for the selected limit line.

Syntax

:CALCulate:LIMit:CLEar

Parameter

Selected limit line

Example

:CALC:LIM1:CLE

:CALCulate:LIMit:DATA

Set

Query

Description

Sets or queries the frequency, amplitude limit of
every point in the selected limit line. The data is
stored in CSV format.
There are total of 10 pairs of data points (20 data
entries in total) for the data.

Syntax

:CALCulate:LIMit:DATA