beautypg.com

Sense]:semask:carrier:cpsd, Sense]:semask:carrier:power – GW Instek GSP-930 Programming Manual User Manual

Page 146

background image

GSP-930 Programming Manual

144

Syntax

[:SENSe]:SEMask:CARRier:AUTO {OFF|ON|0|1}

Query Syntax

[:SENSe]:SEMask:CARRier:AUTO?

Parameter

0

Turn PSDRef/TotalPwrRef to manual
(off).

1

Turn PSDRef/TotalPwrRef to auto (on).

OFF

Turn PSDRef/TotalPwrRef to manual
(off).

ON

Turn PSDRef/TotalPwrRef to auto (on).

Return parameter 0

PSDRef/TotalPwrRef is set to manual.

1

PSDRef/TotalPwrRef is set to automatic.

Example

:SEM:CARR:AUTO OFF

[:SENSe]:SEMask:CARRier:CPSD

Set

Query

Description

Sets or queries the value of the PSDRef for SEM
measurements.

Syntax

[:SENSe]:SEMask:CARRier:CPSD

Query Syntax

[:SENSe]:SEMask:CARRier:CPSD?

Parameter/
Return parameter

PSD ref unit = dBm/Hz

Example

:SEM:CARR:CPSD 20

[:SENSe]:SEMask:CARRier:POWer

Set

Query

Description

Sets or queries the value of the TotalPwrRef
amplitude for SEM measurements.

Syntax

[:SENSe]:SEMask:CARRier: POWer

Query Syntax

[:SENSe]:SEMask:CARRier: POWer?

Parameter

Return parameter

dBm

Example

:SEM:CARR:POW 2 dbm