beautypg.com

Sense]:semask:offset:frequency: stop, Sense]:semask:offset:start: absolute, Sense]:semask:offset:start: relative – GW Instek GSP-930 Programming Manual User Manual

Page 153

background image

REMOTE CONTROL

151

Parameter/
Return parameter

Hz

offset 1~5

Example

SEM:OFFS1:FREQ:STAR 2.5e+3

[:SENSe]:SEMask:OFFSet:FREQuency:
STOP

Set

Query

Description

Sets or queries the stop frequency of the selected
offset.

Syntax

[:SENSe]:SEMask:OFFSet:FREQuency:STOP

Query Syntax

[:SENSe]:SEMask:OFFSet:FREQuency:STOP?

Parameter/
Return parameter

Hz

offset 1~5

Example

SEM:OFFS1:FREQ:STOP 2.5e+3

[:SENSe]:SEMask:OFFSet:STARt:
ABSolute

Set

Query

Description

Sets or queries the amplitude of the start frequency
of the Absolute Mask for the selected offset.

Syntax

[:SENSe]:SEMask:OFFSet:STARt:ABSolute

Query Syntax

[:SENSe]:SEMask:OFFSet:STARt:ABSolute?

Parameter/
Return parameter

dBm

offset 1~5

Example

SEM:OFFS1:STAR:ABS 1.5e+1

[:SENSe]:SEMask:OFFSet:STARt:
RELative

Set

Query

Description

Sets or queries the amplitude of the start frequency
of the Relative Mask for the selected offset.

Syntax

[:SENSe]:SEMask:OFFSet:STARt:RELative