beautypg.com

Calculate:ctb:result, Calculate:ctb:state, Calculate:ctb:restart – GW Instek GSP-930 Programming Manual User Manual

Page 71: Calculate:deltamarker:pair:span

background image

REMOTE CONTROL

69

:CALCulate:CTB:RESult?

Query

Description

Returns the CTB measurement result in dB.

Query Syntax

:CALCulate:CTB:RESult?

Return parameter

CTB measurement in dB

Query Example

:CALC:CTB:RES?
>-4.237e+01

:CALCulate:CTB:STATe

Set

Query

Description

Sets or queries the state of the CTB measurement
function.

Syntax

:CALCulate:CTB:STATe {ON|OFF|1|0}

Query Syntax

:CALCulate:CTB:STATe?

Parameter

0

CTB is off.

1

CTB is on.

OFF

CTB is off.

ON

CTB is on.

Return parameter 0

CTB is off.

1

CTB is on.

Query Example

:CALC:CTB:STAT?
>0

:CALCulate:CTB:RESTart

Set

Description

Restarts the CTB measurement.

Syntax

:CALCulate:CTB:RESTart

:CALCulate:DELTamarker:PAIR:SPAN

Set

Description

Sets the span between the chosen marker and the
delta marker.