REMOTE CONTROL

141

Syntax

[:SENSe]:PMETer:LLIMit

Query Syntax

[:SENSe]:PMETer:LLIMit?

Parameter

power unit, default = dBm

Return parameter

Unit = current unit.

Example

:PMET:LLIM 0

[:SENSe]:PMETer:PSENsor:MODE

Set

Query

Description

Sets or queries the power meter sensor mode.

Syntax

[:SENSe]:PMETer:PSENsor:MODE
{LOWNoise|FASTer}

Query Syntax

[:SENSe]:PMETer:PSENsor:MODE?

Parameter/
Return parameter

LOWNoise Sets the power meter mode to low noise.
FASTer

Set the power meter mode to fast.

Example

:PMET:PSEN:MODE

[:SENSe]:PMETer:RECording:TIME

Set

Query

Description

Sets or queries the power meter recording time.

Syntax

[:SENSe]:PMETer:RECording:TIME
,,

Query Syntax

[:SENSe]:PMETer:RECording:TIME?

Parameter/
Return parameter

Recording time: hours.

Recording time: minutes.
Recording time: seconds.

Example

:PMET:REC:TIME 1,10,30

[:SENSe]:PMETer:RECording:TIME:STEP

Set

Query

Description

Sets or queries the power meter recording interval
in seconds.

Syntax

[:SENSe]:PMETer:RECording:TIME:STEP