Column
Description
Welder
This column displays the name of the Welding Power Source in the selected
Container. The CheckPoint™ administrator entered this text when creating the
Asset Tree (page 4.17).
Welds
This displays the total number of individual welds performed by the Welding
Power Source over the time period selected during the selected shift (if
specified).
Welds Out of Limits
The number in the Welds Out of Limits column reflects the number of welds
performed that went outside of the limits set for the Weld Profile used for the
weld.
The percentage next to the number of welds is the percentage that this number
represents of the total number of welds where limits were enabled, including
those welds that were within the limits set.
NOTE |
If no Weld Profile limits were enabled for the welds performed, the
Welds Out of Limits column displays a zero.
For example, the Welds column displays 62 welds and 50 of those welds had
had limits enabled when they were performed. Of those 50 welds, 15 were
outside of those limits, which also equates to 30% of the 50 welds. The Welds
Out of Limits column would display 15 (30.00%).
WeldScore™
This column displays the average WeldScore™ for the welds listed in the Welds
column where WeldScore™ was enabled. If WeldScore™ was not enabled for a
weld, it is not taken into consideration for this column. If none of the welds in
the Welds column had WeldScore™ enabled, the WeldScore™ column is empty.
For example, if the Welds column displays 62 welds and 42 of those welds had
WeldScore™ enabled when they were performed, the WeldScore™ column
shows the average WeldScore™ for the 42 welds.
Arc Time (min)
This displays the total number of minutes that the Welding Power Source spent
welding based on the welds listed in the Welds column over the time period
selected during the selected shift (if specified).
Deposition (lb)
This column displays the amount of wire (in pounds or kilograms) that was
deposited for the welds made over the time period selected during the selected
shift (if specified).
Wire Remaining (lb)
This displays the amount of wire (in pounds or kilograms) remaining in the
current wire package for the Welding Power Source. Refer to the Power Wave®