beautypg.com

Lincoln Electric IM8000 CHECKPOINT User Manual

Page 133

background image

Overview Report

Chapter 10. Assembly Listing Tab

IM8000

CheckPoint™ User Manual

10.3

Overview Drilldown

When you click the assembly’s link in the Assembly Name column (Figure 10.1 on page 10.1), CheckPoint™
drills down and displays each instance of the Weld Sequences that make up that assembly (Figure 10.2).
Table 10.2 explains each of the columns in more detail.

Figure 10.2 List of Weld Sequences in the Assembly

On this drilldown report, CheckPoint™ displays a colored indicator indicating the current state of this
instance of the Weld Sequence.

ƒ Lightning bolt ( ): The lightning bolt indicator means that this instance of the Weld Sequence

is currently in progress.

ƒ Green ( ): Green means that this instance of the sequence is done and there were no errors

during the Weld Sequence.

ƒ Yellow ( ): Yellow means that the Weld Operator completed this instance of the Weld

Sequence, but there were errors.

ƒ Red ( ): If the indicator is red, this means that the Weld Sequence was aborted.

ƒ Error ( ): An error indicator is unusual and generally occurs if there is a problem with

communications.