Chapter 11. Weld Listing Tab

Summary Report

11.8 CheckPoint™

User

Manual IM8000

Field

Description

the Welding Power Source throughout the duration of this weld (minus the Start
and End delays).

Current Average

Hundreds of times per second, the Welding Power Source takes a measurement
of the arc current while the welder is active for this weld (minus the Start and End
delays). When the weld is complete, the power source averages those
measurements together. The Current Average column displays that average arc
current value for this weld.

Current Maximum

The Current Maximum field displays the highest arc current measurement taken
by the Welding Power Source throughout the duration of this weld (minus the
Start and End delays).

Current Minimum
Limit

This column simply displays the low end of the arc current limit that was set in the
Weld Profile used to make the weld.

Current Maximum
Limit

This column simply displays the high end of the arc current limit that was set in
the Weld Profile used to make the weld.

Current Percent Low

This value is the percentage of measurements taken during the weld (minus the
Start and End delays) that were below the low end of the arc current limit set in
the Weld Profile that was used to make this weld.

Current Percent High

This value is the percentage of measurements taken during the weld (minus the
Start and End delays) that were above the high end of the arc current limit set in
the Weld Profile that was used to make this weld.

Voltage Status

Weld Engineers can set each Weld Profile with a minimum and a maximum
voltage value that is considered acceptable. The Voltage Status field displays
whether this weld was within those limits or out of limits.

Voltage Minimum

The Voltage Minimum field displays the lowest arc voltage measurement taken by
the Welding Power Source throughout the duration of this weld (minus the Start
and End delays).

Voltage Average

Hundreds of times per second, the Welding Power Source takes a measurement
of the arc voltage while the welder is active for this weld (minus the Start and End
delays). When the weld is complete, the power source averages those
measurements together. The Voltage Average column displays that average arc
voltage value for this weld.

Voltage Maximum

The Voltage Maximum field displays the highest arc voltage measurement taken
by the Welding Power Source throughout the duration of this weld (minus the
Start and End delays).

Voltage Minimum
Limit

This column simply displays the low end of the arc voltage limit that was set in the
Weld Profile used to make the weld.

Voltage Maximum
Limit

This column simply displays the high end of the arc voltage limit that was set in
the Weld Profile used to make the weld.