11.9

Field

Description

Voltage Percent Low

This value is the percentage of measurements taken during the weld (minus the
Start and End delays) that were below the low end of the arc voltage limit set in
the Weld Profile that was used to make this weld.

Voltage Percent High

This value is the percentage of measurements taken during the weld (minus the
Start and End delays) that were above the high end of the arc voltage limit set in
the Weld Profile that was used to make this weld.

Wire Feed Speed
Status

Weld Engineers can set each Weld Profile with a minimum and a maximum wire
feed speed that is considered acceptable. The Wire Feed Speed Status field
displays whether this weld was within those limits or out of limits.

Wire Feed Speed
Minimum

The Wire Feed Speed Minimum field displays the lowest wire feed speed
measurement taken by the Welding Power Source throughout the duration of this
weld (minus the Start and End delays).

Wire Feed Speed
Average

Hundreds of times per second, the Welding Power Source takes a measurement
of the speed at which the wire is put into the weld (minus the Start and End
delays). When the weld is complete, the power source averages those
measurements together. The Wire Feed Speed Average column displays that
average wire feed speed value for this weld.

Wire Feed Speed
Maximum

The Wire Feed Speed Maximum column is the highest wire feed speed
measurement taken by the Welding Power Source throughout the duration of this
weld (minus the Start and End delays).

Wire Feed Speed
Minimum Limit

The Wire Feed Speed Minimum Limit column simply displays the low end of the
wire feed speed limit that was set in the Weld Profile used for the weld.

Wire Feed Speed
Maximum Limit

The Wire Feed Speed Maximum Limit column simply displays the high end of the
wire feed speed limit that was set in the Weld Profile used for the weld.

Wire Feed Speed
Percent Low

This value is the percentage of measurements taken during the weld (minus the
Start and End delays) that were below the wire feed speed limit set in the Weld
Profile that was used to make this weld.

Wire Feed Speed
Percent High

This value is the percentage of measurements taken during the weld (minus the
Start and End delays) that were above the wire feed speed limit set in the Weld
Profile that was used to make this weld.

True Energy Average

This column displays the True Energy™ calculated for this weld using the following
equation:

ܶݎݑ݁ ܧ݊݁ݎ݃ݕ [ ܬ] =

1
݊

෍(ݒ

כ ݅

כ ݐ

)

௜ୀଵ

If the Welding Power Source that made the weld had older firmware and did not
support the True Energy™ calculation, this column displays a 0.