Chapter 6 error messages and corrective actions, 1 error messages and corrective actions, 1 error messages and corrective actions -1 – Yokogawa DAQWORX User Manual
Page 122: Index

6-1
IM WX13-01E
Error Messages and Corrective
Actions
1
2
3
4
5
Index
6
6.1
Error Messages and Corrective Actions
A message may appear on the screen during operation. This section describes the
meanings of the messages and their corrective actions.
Code
Message
Corrective Action
E0002
Insufficient memory. Please exit at once.
Exit all other programs and restart AddTrigger. Or, restart Widows.
E0003
Cannot open shared memory.
Exit all other programs and restart AddTrigger. Or, restart Widows.
E0004
Invalid serial number.
Reinstall AddTrigger.
E0101
Please open from the AddTrigger
Launcher.
The program must be started from the Launcher.
E0213
Cannot open the file.
Check whether the file exists, whether the file is of a type that
the software supports, and whether the file system is operating
normally.
E0211
Cannot write to the file.
Check whether there is sufficient space on the hard disk, whether
writing is permitted, and whether the file system is operating
normally.
E4213
Failed to create folder.
Up to 256 characters can be input for folder names.
E4601
Different server type.
The port number that is displayed when you choose Port No. for
Check the connected host name and port
number.
Data Monitor from the File menu on the Launcher is already in use
by another program.
Enter an unused port number.
E4602
The number of allowable client
connections was exceeded.
The number of clients that are connected to the monitor server of
the destination data logger software has been exceeded.
Disconnect a client that is connected to the monitor server of the
data logging software and connect AddTrigger.
E4603
A client with the same ID is connected
from another PC.
A copy of AddTrigger with the same serial number is already
connected to the monitor server of the data logging software.
Reinstall the software using another serial number or disconnect
the copy of AddTrigger that is currently connected.
E4605
Connection was dropped.
Check whether the monitor server of the destination data logging
software is running and whether the network is connected properly.
E4606
Could not initialize communications.
Check whether TCP/IP is operating normally.
E4607
Connection failed. Check the connection
host name and port number, and whether
the monitor server is running.
Check whether the monitor server of the destination data logging
software is running and whether the network is connected properly.
E4608
Time limit has passed.
Check whether the monitor server of the data logging software is
running and whether the network is connected properly.
E4609
Maximum packet size exceeded.
The destination is not a monitor server that AddTrigger supports.
Check whether the destination is a monitor server.
E4610
Invalid system number.
System number not entered correctly. See the user’s manual for
the connected data logging software.
E4611
Command not supported.
The destination is not a monitor server that AddTrigger supports.
E4613
Could not create folder.
Check whether the folder name is valid, write permissions were
granted for the destination folder, sufficient disk space is available,
and whether the file system is functioning properly.
E4614
Invalid folder name.
Folder name that starts with a period is not allowed. Enter a correct
folder name.
E4615
Connection to this monitor server is not
allowed.
Check whether the destination is a monitor server that AddTrigger
supports.
E4619
Password and confirmation mismatch.
Enter the same characters for the password and password
confirmation.
E4620
Invalid password.
Enter the correct password.
E4621
Cannot exit while scanning or recording
is in progress.
Stop scanning first, then exit the Launcher.
E4622
Cannot contain any of the following
characters:
\ / : , ; * ? " < > |
¢\ / : , ; * ? “ < >. Please reenter using allowable characters only.
E4624
Cannot exit AddTrigger while desktop
protection is active.
Disable desktop protection first, then exit the Launcher.
E4625
Cannot exit AddTrigger while password
protection is active.
Disable password protection first, then exit the Launcher.
Chapter 6
Error Messages and Corrective Actions