Math menu – Watlow EZ-ZONE RME User Manual
Page 39
Watlow EZ-ZONE
®
RME Module
•
36
•
Chapter 3 Operations Page
RME Module
•
Operations Page
Display
Parameter Name
Description
Range
Default
Modbus
Relative
Address
CIP
Class
Instance
Attribute
hex (dec)
Profibus
Index
Param-
eter
ID
Data
Type
&
Read/
Write
[`Su;g]
[ Su.g]
Logic (1 to 8)
Source Value G
View the value of Source
G.
[`off]
Off (62)
[``on]
On (63)
- - - -
3080
[off 80]
0x7F
(127)
1 to 8
0x1F (31)
- - - -
27031
uint
R
[`Su;h]
[ Su.h]
Logic (1 to 8)
Source Value H
View the value of Source
H.
[`off]
Off (62)
[``on]
On (63)
- - - -
3082
[off 80]
0x7F
(127)
1 to 8
0x20 (32)
- - - -
27032
uint
R
[``o;u]
[ o.v]
Logic (1 to 8)
Output Value
View the value of this
function's output.
[`off]
Off (62)
[``on]
On (63)
- - - -
3086
[off 80]
0x7F
(127)
1 to 8
0x22 (34)
- - - -
27034
uint
R
No Dis-
play
Logic (1 to 8)
Error
Read reported cause for
logic error
None (61)
Open (65)
Shorted (127)
Measurement error (140)
Bad Cal Data (139)
Ambient Error (9)
RTD Error (141)
Fail (32)
Math Error (1423)
Not Sourced (246)
Stale (1617)
- - - -
3090
[offset 80]
0x7F
(127)
1 to 4
0x24 (36)
- - - -
27036
uint
R
[MAt]
[oPEr]
Math Menu
[`Su;A]
[ Su.A]
Math (1 to 8)
Source Value A
View the value of Source
A.
-1,999.000 to 9,999.000°F
or units
-1,128.000 to 5,537.000°C
- - - -
2210
[off 70]
0x7D
(125)
1 to 8
0x10 (16)
- - - -
25016
float
R
[`Su;b]
[ Su.b]
Math (1 to 8)
Source Value B
View the value of Source
B.
-1,999.000 to 9,999.000°F
or units
-1,128.000 to 5,537.000°C
- - - -
2212
[off 70]
0x7D
(125)
1 to 8
0x11 (17)
- - - -
25017
float
R
[`Su;C]
[ Su.C]
Math (1 to 8)
Source Value C
View the value of Source
C.
-1,999.000 to 9,999.000°F
or units
-1,128.000 to 5,537.000°C
- - - -
2214
[off 70]
0x7D
(125)
1 to 8
0x12 (18)
- - - -
25018
float
R
[`Su;d]
[ Su.d]
Math (1 to 8)
Source Value D
View the value of Source
D.
-1,999.000 to 9,999.000°F
or units
-1,128.000 to 5,537.000°C
- - - -
2216
[off 70]
0x7D
(125)
1 to 8
0x13 (19)
- - - -
25019
float
R
[`Su;E]
[ Su.E]
Math (1 to 8)
Source Value E
View the value of Source
E.
[`off]
Off (62)
[``on]
On (63)
- - - -
2218
[off 70]
0x7D
(125)
1 to 8
0x14 (20)
- - - -
25020
uint
R
[oFSt]
[oFSt]
Math (1 to 8)
Offset
Set an offset to be applied
to this function's output.
-1,999.000 to 9,999.000°F
or units
-1,128.000 to 5,537.000°C
0
2224
[off 70]
0x7D
(125)
1 to 8
0x17 (23)
- - - -
25023
float
RWES
Note:
Some values will be rounded off to fit in the four-character display . Full values can be
read with other interfaces .
Note:
If there is only one instance of a menu, no submenus will appear .
** These parameters/prompts are available in these menus with firmware revisions 6 .0 and
above .
R: Read
W: Write
E: EE-
PROM
S: User
Set