Operating system boot phase, Run-time errors, Operating system boot phase run-time errors – HP A7818-IE002 User Manual
Page 82

Tests And Error Messages
POST Sequence And POST Error
Chapter 4
82
Operating System Boot Phase
If no error message appears at this stage of the system startup, the operating system
launches. The LCD status panel displays the system platform and a smiling icon.
Run-time Errors
During the normal usage of the workstation (and at boot), MaxiLife continually monitors
vital system parameters. These include: temperature errors, fan malfunctions, power
voltage drops and CPU problems.
Presence of continuity modules
in the RIMM sockets
RIMM continuity
3
Check that the RDRAM
continuity modules are
installed
Compatibility speed rating of
installed RDRAM modules
RIMM speed
3
Check that the installed
RDRAM modules have the
same speed ratings
Compatibility of installed
RDRAM modules
RIMM devices
3
The 32-device limit per
RDRAM has been exceeded
Presence of memory modules
No RIMM
3
Check that the memory
modules are correctly installed
Availability of video controller
is checked by the BIOS. If an
error is detected, and it isn’t a
fatal error, the BIOS continues
its execution normally.
No video
4
Check that the video controller
is correctly installed
Note: No error is detected if a
monitor isn’t connected to an
installed video controller. This
isn’t a fatal error, and the
BIOS continues its normal
execution.
Table 4-2
(Continued)
Test
Error Code
Beep Codes