beautypg.com

Power consumption and cooling, Table – HP A7818-IE002 User Manual

Page 21

background image

System Overview

Specifications And Characteristics

Chapter 1

21

If an overload triggers the power supply’s overload protection, all power is immediately
cut. To reset the power supply unit:

1. Disconnect the power cord.

2. Determine what caused the overload, and fix the problem.

3. Reconnect the power cord, and reboot the workstation.

If an overload occurs twice, then there is an undetected short circuit somewhere.

When you use the front panel's power button to turn off the workstation, power
consumption falls below the low power consumption (refer to the table on page 21), but
doesn't reach zero. This on/off feature extends the power supply's lifetime. To reach zero
power consumption in “off ” mode, either unplug the workstation or use a power block
with a switch.

Power Consumption And Cooling

The power consumption and acoustics listed in the following table are valid for a
standard configuration as shipped (one processor, 256MB of memory, 492 W power
supply, one hard disk drive, graphics card, LAN card).

All information in this section is based on primary power consumptions.

Power consumption (approximate
values)

230V/50Hz and 115V/60Hz

Typical operating mode

Suspend mode (Windows 2000
models only)

70W
<4W

- 238.8Btu/h

a

- 13.6Btu/h

a. 1W = 3.4121Btu/h

Additional Component

Processor

SCSI hard disk drive with I/O
access

SCSI hard disk without I/O
access (idle)

PCI card

50W

23W

16W

10W to

36W

- 170.6Btu/h

- 78.4Btu/h

- 54.5Btu/h

- 64.1Btu/h to
122.8Btu/h