beautypg.com

If you miss the beep code, Post test errors, Table – HP A7818-IE002 User Manual

Page 162

background image

Troubleshooting Your Workstation

Case 3: Boot Fails, Monitor Is Blank, MaxiLife Displays Error Message

Chapter 7

162

If You Miss The Beep Code

If you miss the beep code, turn off the workstation by pressing the on/off power button
for five seconds or more, then listen for the signal again.

Post Test Errors

Following the pre-boot checks, the POST (Power-On Self Test) sequence is initiated. It
should be noted that in some cases, a Beep and Post Error can occur at the same time.

The following table shows the type of error messages that can be displayed on the
MaxiLife status panel, and the action to take.

The Boot Step option must be selected for these messages to be displayed by MaxiLife.

MaxiLife Error Message

Action to Take

P.O.S.T. Start

Change system board

CPU Regist. Init

Change system board

I/O Init.

Change system board

IDE Init.

Change system board

PCI Mast. Init.

Change system board

BIOS Check sum

Change system board

RAM Refresh Test

Change system board

Keyb. Ctrl. Test

Keyboard missing.

If this is not the case, change system board.

Memory Detection

Check memory then system board

RAM Add. Failure

Check memory then system board

RAM Data Low

Check memory then system board

RAM DATA High

Check memory then system board

Shadow Bios Rom

Flash BIOS again then check system board

PCI Detection

Check PCI cards.

If this does not work, change system board.

Video Detection

Check AGP card then system board

Keyboard Test

Keyboard missing or change keyboard

Unexpect. STOP

Change system board

Base Memory Test

Check memory then system board

Ext. Memory Data

Check memory then system board

Ext. Memory Add

Check memory then system board

Mouse PS2 Test

Change mouse.

If this does not work, change system board.

Disc Ctrl. Init.

Check SCSI card (if installed).

If this does not work, change system board.

Disc Bus Init.

Check SCSI card (if installed).

If this does not work, change system board.

MaxiLife Test

Change system board.

If this does not work, change control panel.

CDROM Ctr. Init.

Check CD-ROM.

If this does not work, change system board.

Opt. Rom Detect.

Change system board.