beautypg.com

Figure41 possible error messages, Figure42 preboot diagnostics error – HP A7818-IE002 User Manual

Page 79

background image

Tests And Error Messages

MaxiLife Test Sequence And Error Messages

Chapter 4

79

On the HP Workstation x2100, the first detected error displays a message on the LCD
status panel. If an error occurs, one of the following screens displays.

Figure 4-1

Possible Error Messages

Figure 4-2 shows how the preboot diagnostics work when an error occurs.

Figure 4-2

Preboot Diagnostics Error

The following table shows the test sequence carried out, the type of error message, and
the action to take.

Missing or incorrectly installed
processor

Presence of processor

Control of some voltages:
12V, 3.3V, 1.8V, 2.5V, -5V

If a power supply error occurs, a
cause could reside in the power
supply cabling or circuits

ERROR

Power Supply

ERROR

CPU Socket

MaxiLife
Firmware

LCD Status
Panel

I2C Bus

Voltage CPU1

Voltage 12V, 3.3V, 1.8V, 2.5V

CPU or Terminator

Vcc State (5V)

An error has been detected when
checking the processor. The
displayed error message could
indicate a missing or incorrectly
connected processor.

System
Memory

ERROR

CPU Socket

Temperature

Sensors

Hardware

Monitoring

Table 4-1

Test

Error Code

Beep Codes

Action to Take

Presence a processor

CPU socket

1

Check that the processor and
correctly installed

Control of some voltages: 12V,
3.3V, 1.8V, 2.5V

Power supply

2

Check the power supply cable
and connectors, and processor

Check the hardware monitoring

No HW monitoring

System board problem

Check thermal sensor

Therm. sensor 90

System board problem

Check thermal sensor

Therm. sensor 92

System board problem