beautypg.com

Panasonic AV-HS6000 2 M/E Live Switcher Main Frame & Control Panel (Dual Redundant Power Supplies) User Manual

Page 59

background image

– 59 –

Chapter 5 Basic Operations — Wipe

3

Select an item in [Pattern] in the [H Modulation]/[V Modulation] column.

[Sine]

Selects sine waves.

[Delta]

Selects delta wave.

Setting the transition MID Position

Adjusts the position and size of the pattern waveform when the transition amount is in the range of 40% to 60% (mid position).

f

Enabled when the following pattern waveforms are selected.

-

SQ: 51, 52, 53, 54

1

Select the / button

[BKGD]

[Modify] tab.

2

Set [X] and [Y] in the [MID Position] column.

Sets the position of the pattern waveform.

f

SQ: 51 will place two sub-screens symmetrical to the Y axis.

f

SQ: 52 will place two sub-screens symmetrical to the X axis.

f

SQ: 53 will place two sub-screens symmetrical to the center point.

3

Set [Size] in the [MID Position] column.

Sets the size of the pattern waveform.

Setting the free pattern

Selecting the following pattern waveform allows to arbitrarily change some parameters such as the wipe shape, and position and size of the image in
PGM bus or PST bus.

f

WIPE: 24 (Free Wipe)
Combines the images in the PGM bus and the PST bus with the window wipe.

f

3D: 113 (Free S-DVE)
Combines the images in the PGM bus and the PST bus using 1ch of DVE.

f

3D: 114 (Free D-DVE)
Combines the images in the PGM bus and the PST bus using 2ch of DVE.

The transition amount by the button or the fader lever is disabled when these waveforms are selected and the button is pressed.

1

Press the button.

2

Select the / button

[BKGD]

[BKGD Pattern] tab.

3

Set an item in [Pattern] of the [BKGD Pattern] column.

f

Select one of WIPE: 24, 3D: 113, or 3D: 114.

4

Operate the fader lever.

f

Set to a position other than the end point.

5

Select the / button

[BKGD]

[Free PATT] tab.

f

Set the parameter in item of each column.

r

Parameters that can be adjusted in each pattern

Free Wipe

Free S‑DVE

Free D‑DVE

Description

CH1 Reset, CH2 Reset

CH1 only

CH1 only

l

Initializes the parameter

CH1 to CH2, CH2 to CH1

l

Copies the parameter

Prio INV

l

Changing the CH1, CH2 priority

Position X, Y, Size

l

l

l

Position and size of CH1

2nd Position X, Y, Size

l

Position and size of CH2

Rotation X, Y, Z

Z only

l

l

Rotation of CH1

2nd Rotation X, Y, Z

l

Rotation of CH2

Trim Left, Top, Right, Bottom

l

l

Trimming of CH1

2nd Trim Left, Top, Right, Bottom

l

Trimming of CH2

r

Relationship between the wipe direction , and PGM bus, PGM bus

Relationship between the wipe direction , and PGM bus, PGM bus is as follows.

Free Wipe