Panasonic AV-HS6000 2 M/E Live Switcher Main Frame & Control Panel (Dual Redundant Power Supplies) User Manual

Page 180

background image

– 180 –

Chapter 11 Specifications — Specifications

Synchronous terminal

terminal

In Genlock mode: Black burst or Tri-level Sync input signals (with loop-through)

f

If the loop-through output is not used, provide a 75

Ω

termination.

In internal sync mode: Black burst output signal

×

2

f

Connector: BNC

f

Same field frequencies as those of the system formats supported

f

In the 1080/24PsF and 1080/23.98PsF formats, only Genlock mode supported

f

In the 1080/23.98PsF format, black burst signals with 10 Field ID (SMPTE318M standard compliant) or Tri-level Sync

signals supported

terminal

This is the LTC (linear time code) input terminal

f

Connector: BNC

f

Impedance: 1 k

Ω

f

Level: 1 to 2 V [p-p]

Video delay time

During Standard mode

1 line (H)

When the frame synchronizer is set to [Off], and the up-converter is set to [Off]

1 frame (F)

When the frame synchronizer is set to on, or the up-converter is set to [On]

f

When the signals have passed through PinP, DVE, MultiView, down-converter, or DVI-IN, a maximum delay of 1 frame is

applied in each case.

During 3G mode

2 lines (H)

When the frame synchronizer is set to [Off]

2 frames (F)

When the frame synchronizer is set to [On]

f

Maximum of 2 frame delay is added to each when passed through PinP, DVE, or MultiView.

During 4K mode

1 frame (F)

The frame synchronizer is always on.

f

Maximum of 2 frame delay is added to each when passed through PinP, DVE, or MultiView.

f

For details on other added delays, refer to “3G mode/4K mode” (page 162).

Control terminal

terminal

Compatible with 100Base-TX and AUTO-MDIX (For IP control)

f

Connection cable: LAN cable (CAT5E), max. 100 m (328 ft), STP (Shielded Twisted Pair) cable recommended

f

Connector: RJ-45

terminal

Compatible with 100Base-TX and AUTO-MDIX (For Control Panel AV-HS60C1/AV-HS60C2/AV-HS60C4 connection)

f

Connection cable (supplied with AV-HS60C1/AV-HS60C2/AV-HS60C4): LAN cable (CAT5E), straight cable, STP

(Shielded Twisted Pair), 10 m (32.8 ft)

f

Connector: RJ-45

//

(M)> terminals

RS-422 control terminal

For master connection for controlling external devices

f

Connector: D-sub 9-pin (female)

×

3, inch screw

terminal

RS-422 control terminal

For master/slave connection for controlling external devices

f

Connector: D-sub 9-pin (female), inch screw

f

Switchable between master connection and slave connection by the menu

terminal

GPI IN: 18 inputs, general-purpose, photocoupler sensing

ALARM OUT: 1 output, open collector output (negative logic)

f

Connector: D-sub 25-pin (female), inch screw

/

terminals

GPI OUT: 48 outputs, selected from general purpose, tally

Open collector output

f

Connector: D-sub 25-pin (female)

×

2, inch screw

@

@

NOTE

t

Use with the same segment is recommended for the devices which are connected to the unit. If the unit is connected to the devices whose segments
are different, events dependent upon the settings inherent to the network equipment, for instance, may occur. Thoroughly check the connections with
the devices to which the unit will be connected prior to the start of operation.

Other

Ambient operating temperature

0 °C to 40 °C (32 °F to 104 °F)

Humidity

10% to 90% (no condensation)

Dimensions (W

×

H

×

D)

482 mm

×

132 mm

×

418 mm (18-31/32 inches

×

5-3/16 inches

×

16-15/32 inches) (excluding protrusions)

3RU

Mass

AV-HS60U1: Approx. 12.6 k

]

(27.8 lbs.) (excluding accessories)

AV-HS60U2: Approx. 13.5 k

]

(29.7 lbs.) (excluding accessories)

r

For AV‑HS60U1E/AV‑HS60U2E

Inrush current, measured according to European standard EN55103-1, on initial switch-on: 3 A, after a supply interruption of 5 s: 35 A (Each mains
input)