beautypg.com

Setting the tally display, Other display settings – Panasonic AV-HS6000 2 M/E Live Switcher Main Frame & Control Panel (Dual Redundant Power Supplies) User Manual

Page 128

background image

– 128 –

Chapter 6 Input/Output Signal Settings — Setting MultiView displays

Setting the tally display

Configure the tally display setting to be superimposed onto the split frame of the MultiView display.

SDI IN 1

[Tally Box]

[Tally Label L]

[Tally Label R]

[Source Name]

1

Select the button

[MV1‑4]

[MV1] to [MV4] tabs.

2

Select an item in [Tally Group1] to [Tally Group4] in the [Tally Box]/[Tally Label L]/[Tally Label R] column.

[On]

Shows the tally displays.

[Off]

Does not show the tally displays.

@

@

NOTE

t

If conditions overlap, the following priority order is used:
[Tally Group1] > [Tally Group2] > [Tally Group3] > [Tally Group4]

t

To set the tally color, select the button on the top menu

[PERIPHERAL]

[Tally] tab

[Tally Group2-1] to [Tally Group4-1] columns

[Color].

t

For details on the tally group settings, refer to “Setting a tally” (page 153).

Other display settings

Setting the level meter

Level meters for the embedded audio signals transferred by the SDI input can be displayed on the split screens.

f

Display on the left: Channel 1 of group 1

f

Display on the right: Channel 2 of group 1

1

Select the button

[MV1‑4]

[MV1] to [MV4] tabs.

2

Select an item in [Level Meter] in the [Display] column.

[Off]

Does not display the level meter.

[On]

Displays the level meter.

Setting the input signal mark

The status of the input signals can be displayed in front of the source names displayed on the split screens.

f

[F] mark: Indicates that the input signals are frozen.

f

[!] mark: Indicates that there are no input signals or signals with different formats are input. If horizontal pixels are the same, false detection may occur.

1

Select the button

[MV1‑4]

[MV1] to [MV4] tabs.

2

Select an item in [Input Status] in the [Display] column.

[On]

Displays the input signal status.

[Off]

Does not display the input signal status.

f

When the [F] mark is displayed, the [!] mark is not displayed.

Setting the marker

Safety markers can be displayed for PGM and PVW sources of the MultiView display.

1

Select the button

[MV1‑4]

[MV1] to [MV4] tabs.

2

Select an item in [Marker] in the [Display] column.

f

Configure the marker display setting.

[Off]

Does not display the markers.

[4:3]

Displays the markers using the 4:3 aspect ratio.

[16:9]

Displays the markers using the 16:9 aspect ratio.

3

Set [Marker Size] in the [Display] column.

f

Set the marker size.