Connection (to installation personnel), Connecting the imaging systems, Connecting the control systems – Panasonic AV-HS6000 2 M/E Live Switcher Main Frame & Control Panel (Dual Redundant Power Supplies) User Manual
Page 15
– 15 –
Chapter 2 Installation and Connection (To installation personnel) — Connection (To installation personnel)
Connection (To installation personnel)
Connecting the imaging systems
Connect cameras, VTR, and other external sources.
The SDI input of the Main Frame AV-HS60U1/AV-HS60U2 has a frame synchronizer function, and a non-synchronized SDI signal can be input. To
reduce image delay, set the frame synchronizer function to [Off], send a sync signal to the unit and the input device, and configure a synchronized
system.
Computer
Camera
Connect the switcher output signal to monitors and other external devices.
HD-SDI monitor
Connect the system sync signal from the sync signal generator.
The loop-through output is performed in the external sync mode. If the loop-through output is not going to be used, provide a 75
Ω
termination.
Black burst signals are output from both terminals in the internal sync mode.
Internal sync mode
Internal signal
generator
INT
Sync signal
External sync mode
Connecting the control systems
Connect the Control Panel AV-HS60C1/AV-HS60C2/AV-HS60C4, computer for menu operation, or external devices to the Main Frame AV-HS60U1/
AV-HS60U2.
The connection of the main control panel and the sub control panel is described here using the illustration of AV-HS60C1/AV-HS60C2.
AV-HS60C4 can also be connected in the same manner.