Page 50: Setting a tally

background image

– 50 –

Chapter 4 Preparations — Various settings

[On]

Enables link settings.

[Off]

Disables link settings.

Button settings

Assigning video sources to buttons

External video input signals and internally generated signals can be assigned to the crosspoint buttons (the PGM/A, PST/B, and KEY bus crosspoint
buttons) in the crosspoint area.

f

For details, refer to “Assigning signals to buttons” (page 131).

1

Select the button

[XPT ASSIGN]

[MainPanel]/[SubPanel1]/[SubPanel2] tab, and make the following settings.

[MainPanel] tab

Assigns the main control panel.

[SubPanel1] tab

Assigns the sub control panel 1 (second Control Panel AV-HS60C1/AV-HS60C2/AV-HS60C4).

[SubPanel2] tab

Assigns the sub control panel 2 (third Control Panel AV-HS60C1/AV-HS60C2/AV-HS60C4).

Disabling button/block operations

Operations can be disabled for each button or block.

f

For details, refer to “Disabling button operations” (page 130).

1

Select the button

[BUTTON INHIBIT]

[MainPanel]/[SubPanel1]/[SubPanel2] tab, and make the following settings.

[MainPanel] tab

Assigns the main control panel.

[SubPanel1] tab

Assigns the sub control panel 1 (second Control Panel AV-HS60C1/AV-HS60C2/AV-HS60C4).

[SubPanel2] tab

Assigns the sub control panel 2 (third Control Panel AV-HS60C1/AV-HS60C2/AV-HS60C4).

Setting button colors

For details on the button color settings, refer to “Setting the button color” (page 151).

Setting output signals

Make various settings for SDI output signals.

f

For details, refer to “Setting output signals” (page 125).

1

Select the button

[SDI OUT]

[Assign]/[Down Converter] tab, and make the following settings.

[Assign] tab

Assigns output matrix.

[Down Converter] tab

Makes the settings for down-converters built into the / terminals.

2

Select the button

[C/C OUT]

[SDI OUT 13] to [SDI OUT 16] tabs, and make the color corrector settings.

f

Make the settings for color correctors built into the to terminals.

f

For details on the settings output from the ME/DSK block such as ME1CLN and ME2CLN, refer to “Setting the ME output and DSK output”
(page 148).

Setting MultiView displays

If the output signal is set to MV1 to MV4, multiple images can be simultaneously displayed on a maximum of 16 split screens.

f

For details, refer to “Setting MultiView displays” (page 127).

1

Select the button

[MV1‑4]

[MV1] to [MV4] tabs.

2

In the [Pattern] column, make the settings for the split pattern of the MultiView display.

f

When [Assign] is selected, the source settings screen will be displayed on a sub-screen.

3

In the [MV Frame]/[Tally Box]/[Tally Label L]/[Tally Label R]/[Display] column, set the information displayed on the sub‑screen.

Setting a tally

Setting reference outputs

For details on the tally group settings, refer to “Setting a tally” (page 153).

1

Select the button

[PERIPHERAL]

[Tally] tab.

2

Select an item in [Target A], [

+

Target B], [

+

Target C], and [

+

Target D] of the [Tally Group1‑1 (On‑Air)] column, and select an item in

[

+

Target E], [

+

Target F], [

+

Target G], and [

+

Target H] of the [Tally Group1‑2 (On‑Air)] column.

f

Select up to eight reference outputs to be used for the on-air tally.

3

Select an item in [Target A], [

+

Target B], [

+

Target C], [

+

Target D] of the [Tally Group2‑1] to [Tally Group4‑1] columns, and select an

item in [

+

Target E], [

+

Target F], [

+

Target G], and [

+

Target H] of the [Tally Group2‑2] to [Tally Group4‑2] columns.