Initialization – Panasonic AV-HS6000 2 M/E Live Switcher Main Frame & Control Panel (Dual Redundant Power Supplies) User Manual
Page 157
– 157 –
Chapter 8 System Menu — Maintenance settings
2
Select an item in the [Alarm Enable] column below each [Main frame]/[Main Panel]/[Sub Panel1]/[Sub Panel2] column.
[On]
Alarm detection is enabled.
[Off]
Alarm detection is disabled.
Log file recording
Each type of information in this unit such as alarms, are recorded in the built‑in log file.
Log files can be saved in a memory card and a local computer connected to the LAN terminal of the Main Frame AV‑HS60U1/AV‑HS60U2.
r
To save a log file to a memory card
1
Select the
→
[MAINTENANCE]
→
[Alarm] tab.
2
Select an item in [Log File] in the [Log] column.
3
Select [OK].
f
Save the log file to a memory card.
r
To save a log file to a local computer
1
Connect the Main Frame AV‑HS60U1/AV‑HS60U2 and a computer.
For details, refer to “Connecting a computer” (page 17).
2
Enter the address (http://192.168.0.5/log/log.txt) in the Web browser of a computer.
f
A log file is saved in an internal storage of the computer.
f
Enter the IP address for the
changed from the default setting (192.168.0.5), enter the changed value. For details on IP address setting, refer to “Configuring the network for the
Main Frame AV-HS60U1/AV-HS60U2” (page 48).
Initialization
Initializing the setting data
The setting data can be reset to factory settings.
1
Select the
→
[MAINTENANCE]
→
[Boot] tab.
2
Select an item in the [Initial] column.
f
Select the mode to be initialized.
[Initial]
Initializes the unit.
f
Plug-in software is not deleted.
f
Network setting values are not initialized.
[with Plugin]
Initializes the unit. All plug-in software applications are deleted.
f
Network setting values are not initialized.
[with Plugin/NW]
Initializes the unit including network setting values. All plug-in software applications registered in the unit are deleted.
3
Select [OK] in the confirmation screen.
f
Initialize the settings data.
@
@
NOTE
t
Data of the video memory is erased when the setting data is initialized. Data stored in the Storage Module AV-HS60D1 (optional) is not initialized.
t
The setting of date and time is not initialized. (page 159)
t
Initialization cannot be performed during video (Clip) recording/playback or during event memory playback.
t
When you have deleted plug-in software, turn off the power, and restart the unit.
Initializing the fader lever
The transition range of the fader lever can be initialized.
f
Initialization should be performed when the fader lever becomes out of adjustment by moving the installation location, etc., and transitions are not
completed even if the fader lever has been pushed as far as it will go.
1
Select the
→
[MAINTENANCE]
→
[Boot] tab.
2
Select [Fader Initial] in the [Fader Initial] column.
3
Select [OK] in the confirmation screen.
4
Move the fader lever back and forth once.