beautypg.com

Main frame av‑hs60u1/av‑hs60u2, Front panel, Rear panel – Panasonic AV-HS6000 2 M/E Live Switcher Main Frame & Control Panel (Dual Redundant Power Supplies) User Manual

Page 20

background image

– 20 –

Chapter 3 Part Names and Functions — Main Frame AV‑HS60U1/AV‑HS60U2

Main Frame AV‑HS60U1/AV‑HS60U2

Front panel

1

2

3

Power supply 1

Power supply 2

1

Alarm indicator

Lights up when the cooling fan of the Main Frame AV-HS60U1/AV-HS60U2 has stopped or when there are problems (voltage declines) with the
power supply. In such cases, an alarm message is displayed on the Menu Panel AV-HS60C3. For the redundant power supply model (AV-HS60U2),
an alarm will be displayed if both switches of the power supply 1 and the power supply 2 have not turned on.
When an alarm has occurred, details of the problem can be checked from the button on the top menu

[MAINTENANCE]

[Alarm] tab.

(page 156)
Alarm status can be output from the alarm output port of the terminal on the Main Frame AV-HS60U1/AV-HS60U2 to external devices.

f

AV-HS60U1 does not have the alarm indicator for the power supply 2.

2

Power indicator

Lights up when power is input into the / terminal and also when the switches of the power supply 1 and the power
supply 2 are set to .

f

AV-HS60U1 does not have the power indicator for the power supply 2.

3

switch

Turns power on/off.

f

The single power supply model (AV-HS60U1) does not have the switch for the power supply 2.

f

When turning off the power of the redundant power supply model (AV-HS60U2), set both switches for the power supply 1 and the
power supply 2 to .

@

@

NOTE

t

When an alarm has occurred, stop using the unit immediately, and be sure to contact your dealer.

Rear panel

1

3

4

5

6

7

8

9

10

11 12

14

2

13

1

to terminals (connector: BNC

×

32/signal: SDI IN)

to terminals are equipped with color correctors.
The /// terminals are equipped with up-converters.

2

/ terminals (connector: DVI‑D

×

2/signal: DVI‑D IN)

Connects DVI-D output devices such as a computer using DVI-D cables.

f

The DVI-I connector cable cannot be used.

3

to terminals (connector: BNC

×

32/signal: SDI OUT)

Assigns SDI OUT signals from the button on the top menu

[SDI OUT]

[Assign] tab. (2 distributions each) (page 125)

to terminals are equipped with color correctors.
/ terminals are equipped with down-converters.

4 terminal (connector: RJ‑45/signal: 100Base‑TX)

Connects second and further Control Panels AV-HS60C1/AV-HS60C2/AV-HS60C4, menu operation computers, and external devices.

f

Images from the Control Panel AV-HS60C1/AV-HS60C2/AV-HS60C4 connected to this terminal cannot be displayed on the Menu Panel
AV-HS60C3.