beautypg.com

Setting the external connection, Setting a serial port, Setting a tally – Panasonic AV-HS6000 2 M/E Live Switcher Main Frame & Control Panel (Dual Redundant Power Supplies) User Manual

Page 153

background image

– 153 –

Chapter 8 System Menu — Setting the external connection

Setting the external connection

Setting a serial port

The port can be switched between master and slave connection.

1

Select the button

[PERIPHERAL]

[General] tab.

2

Select an item in [Master/Slave] in the [MF COM4] column.

[Master]

A master connection is used.

[Slave]

A slave connection is used.

Setting a tally

Setting the tally mode

1

Select the button

[PERIPHERAL]

[Tally] tab.

2

Select an item in [MV Tally] in the [Tally Mode] column.

[Internal]

The tally of each sub-screen of the MultiView display is updated according to the tally generated by the unit.

[External]

The tally of each sub-screen of the MultiView display is not updated by tally generated by the unit and is updated

according to the information from external devices connected to the unit.

The tally control from external devices is supported by the plug-in software.

3

Select an item in [Key Judge] in the [Tally Mode] column.

[ON]

On/off of the tally is determined by corresponding source is included in the valid screen.

[OFF]

On/off of the tally is determined from the transition amount or on/off of the key.

Setting a tally group

1

Select the button

[PERIPHERAL]

[Tally] tab.

2

Select an item in [Target A], [

+

Target B], [

+

Target C], and [

+

Target D] of the [Tally Group1‑1 (On‑Air)] column, and select an item in

[

+

Target E], [

+

Target F], [

+

Target G], and [

+

Target H] of the [Tally Group1‑2 (On‑Air)] column.

f

Set the reference output for [Tally Group1-1 (On-Air)]/[Tally Group1-2 (On-Air)] (on-air tally).
Off, ME1PGM, ME1CLN, ME2PGM, ME2CLN, DSKPGM1, DSKPGM2, DSK1CLN to DSK4CLN, AUX1 to AUX16

f

Since [Tally Group1‑1 (On‑Air)]/[Tally Group1‑2 (On‑Air)] is used exclusively for on‑air tally, a preview output cannot be specified.

f

Tally information of sources that configure any of the outputs set in [Target A], [

+

Target B], [

+

Target C], and [

+

Target D] of the [Tally Group1-1 (On-

Air)] column and [

+

Target E], [

+

Target F], [

+

Target G], and [

+

Target H] of the [Tally Group1-2 (On-Air)] column is generated.

3

Select an item in [Target A], [

+

Target B], [

+

Target C], [

+

Target D] of columns [Tally Group2‑1] to [Tally Group4‑1], and [

+

Target E],

[

+

Target F], [

+

Target G], and [

+

Target H] of columns [Tally Group2‑2] to [Tally Group4‑2].

f

Set the reference output for [Tally Group2-1]/[Tally Group2-2] to [Tally Group4-1]/[Tally Group4-2].
Off, ME1PGM, ME1CLN, ME2PGM, ME2CLN, DSKPGM1, DSKPGM2, DSK1CLN to DSK4CLN, AUX1 to AUX16, ME1PVW, ME2PVW,
DSKPVW1, DSKPVW2

4

Select an item in [Color] in the [Tally Group1‑1 (On‑Air)] to [Tally Group4‑1] columns.

f

Select [Red], [Green], [Yellow], or [Orange] for the color of the MultiView display.

f

Since [Tally Group1] is exclusively for on‑air tally, the color is fixed to [Red].

Tally display of the MultiView display

The target of tally display of the MultiView display is [Tally Box], [Tally Label L], and [Tally Label R].
For each of those areas, [Tally Group1] to [Tally Group4] are set and displayed.

f

For details on the tally display of the MultiView display, refer to “Setting the tally display” (page 128).

High tally display and bus tally display of the button

The High tally and bus tally are displayed for the next button from [Tally Group1-1 (On-Air)] (on-air tally).

f

Applicable buttons are the KEY bus crosspoint buttons, PGM/A bus crosspoint buttons, PST/B bus crosspoint buttons, corresponding buttons from
to , and buttons from to .

GPI input/output tally settings

f

For each tally group, a maximum of 48 source tally outputs can be assigned to the GPI output terminal.

f

The functions can be assigned in each tally group and can be enabled/disabled externally through the GPI input terminal.

f

For details on GPI input/output tally settings, refer to “Setting the GPI input/output” (page 154).