beautypg.com

Setting the delay amount, Freezing input signals, Setting the source name – Panasonic AV-HS6000 2 M/E Live Switcher Main Frame & Control Panel (Dual Redundant Power Supplies) User Manual

Page 120: Setting the up-converter, Setting the up‑converter

background image

– 120 –

Chapter 6 Input/Output Signal Settings — Setting input signals

@

@

NOTE

t

When the frame synchronizer function is [Off], if [Dot by Dot], [U/C], and [Auto] are set, the frame synchronizer function is automatically set to [Strict].

t

When [Freeze] is set to [On] in the [SDI IN 1] to [SDI IN 32] columns, the input mode cannot be changed.

Setting the delay amount

The input signals can be delayed.

f

This function is enabled when [FS] in the [SDI IN 27]/[SDI IN 28]/[SDI IN 31]/[SDI IN 32] column is set to an item other than [Off].

1

Select the button

[SDI IN]

[Frame Buffer] tab.

2

Set [Frame delay] in the [SDI IN 1] to [SDI IN 32] columns.

f

Set the input signal delay amount in a range between [0F] and [8F].

Freezing input signals

The input signals can be frozen and used. While signals are frozen, the tally signals of the corresponding input will not be output.

Setting the freeze mode

1

Select the button

[SDI IN]

[Frame Buffer] tab.

2

Select an item in [Freeze Mode] in the [SDI IN 1] to [SDI IN 32] columns.

f

An item can also be selected while an image is frozen.

[Frame]

Freezes the images frame by frame.

[Field]

Freezes the images field by field.

This is used to freeze moving images. With interlace signals, however, diagonal lines appear jagged.

Setting freeze

1

Select the button

[SDI IN]

[Frame Buffer] tab.

2

Select an item in [Freeze] in the [SDI IN 1] to [SDI IN 32] columns.

[On]

Freezes the input signals.

[Off]

Does not freeze the input signals.

f

The [F] mark appears in front of the source name when the signals set for output of MultiView displays are frozen.

f

When the unit is used with the frame synchronizer function [Off], the output images may be disturbed when freezing is executed, but the frozen
images will not be adversely affected.

f

If the freeze setting is set to [On] while the frame synchronizer function is set to [Off], the frame synchronizer function is automatically set to [Strict].

Setting the source name

The source names displayed on the Control Panel AV-HS60C1/AV-HS60C2/AV-HS60C4 and the MultiView display can be set from the button
on the top menu

[SOURCE NAME]

[Panel Name]/[MV Name] tab.

For details, refer to “Setting the source name” (page 132).

Setting the up‑converter

In the [SDI IN 27], [SDI IN 28], [SDI IN 31], [SDI IN 32] columns, configure the built‑in up‑converter setting.

1

Select the button

[SDI IN]

[Up Converter] tab.

2

Select an item in [Scale] in the [SDI IN 27]/[SDI IN 28]/[SDI IN 31]/[SDI IN 32] column.

f

Select the scaling system.

Item

Description

Input image

(SD)

System image

(HD)

[Squeeze]

Enlarges the image both horizontally and vertically to fill the

entire screen.

[Edge Crop]

Maintains the aspect ratio of the image, and enlarges the

image in accordance with the vertical resolution. Black images

are added at the left and right.

[Letter Box]

Maintains the aspect ratio of the image, and enlarges the

image in accordance with the horizontal resolution. The image

is cropped at the top and bottom.