Section 2.10.2.2, attaching the, Cvfm03 module directly to the raid controller – Avago Technologies Cache Protection for RAID Controller Cards User Manual
Page 98

Avago Technologies
- 98 -
Cache Backup Products for MegaRAID SAS+SATA RAID Controllers User Guide
May 2015
Chapter 2: Installing the Cache Backup Products
Attaching the CVFM03 Module to a MegaRAID SAS 9265CV-8i RAID Controller and
Connecting to a Remote CVPM02 Module
2.10.2.2
Attaching the CVFM03 Module Directly to the RAID Controller
Follow these steps to attach the CVFM03 module directly to the RAID controller.
WARNING
There is danger of an explosion if the battery is incorrectly replaced.
Replace the battery only with the same or equivalent type
recommended by the manufacturer. Dispose of used batteries
according to the manufacturer’s instructions.
1.
Ground yourself, and make sure that the system is grounded.
2.
Remove the CVFM03 module from the package.
3.
Place the CVFM03 module front-side-up on a flat, clean, static-free surface.
4.
Place the RAID controller on a flat, clean, static-free surface.
5.
Hold the CVFM03 module so that the top side is facing upward, and align the J2M1 connector on the CVFM03
module with the J5B1 BBU connector on the RAID controller, as shown in the following figure.
Figure 66 Attaching the CVFM03 Module Directly to the RAID Controller
6.
Carefully press the CVFM03 module onto the RAID controller so that the two connectors are firmly joined.
7.
Secure the CVFM03 module to the RAID controller with the screws and the standoffs in the three screw holes.
The standoffs are threaded at both ends, and a screw goes into each end. The screw threads from the back of the
controller board into the board-to-board standoffs on the bottom of the CVFM03 module.
NOTE
Center the screwdriver carefully to avoid stripping the screw heads.
Do not overtighten the screws.
3_00914-00
CacheVault
Flash Module
(CVFM03)
J5B1