Avago Technologies Cache Protection for RAID Controller Cards User Manual
Page 128

Avago Technologies
- 128 -
Cache Backup Products for MegaRAID SAS+SATA RAID Controllers User Guide
May 2015
Chapter 3: Monitoring and Managing Battery Backup Units and CacheVault Modules
Monitoring and Managing BBU Units with the MegaRAID Configuration Utilities
Figure 87 Advanced Battery Management
The small red arrow at the bottom of the dialog indicates that you can scroll down to view more Advanced Battery
Management properties.
NOTE
The red arrow appears when there is too much information to display
in one dialog. The amount of information that can appear in one
dialog depends on the capabilities of the HII browser.
The following table describes the advanced battery properties and the other options on this dialog. Properties
marked with an asterisk are user-selectable. All other properties are view only.
Table 15 Advanced Battery Management Properties
Property
Description
Start Manual Learn Cycle*
Highlight this field and press Enter to start a manual battery learn cycle.
Set Automatic Learn Cycle
Properties*
Highlight this field and press Enter to set the properties for an automatic battery learn cycle.
Manufacturer
Manufacturer of the battery.
Serial Number
Serial number of the battery.
Date of Manufacture
Manufacturing date of the battery.
Firmware Version
Firmware version of the battery.
Status
Status of the battery. If the status is Learning, Degraded, or Failed, a reason is listed for the status.
Voltage
Voltage level of the battery, in mV. Also indicates if the current battery voltage is normal or low.
Current
Current of the battery, in mA.
Design Capacity
Theoretical capacity of the battery.
Full Capacity
Full charge capacity of the battery.