3 display bbu capacity – Avago Technologies Cache Protection for RAID Controller Cards User Manual
Page 118

Avago Technologies
- 118 -
Cache Backup Products for MegaRAID SAS+SATA RAID Controllers User Guide
May 2015
Chapter 3: Monitoring and Managing Battery Backup Units and CacheVault Modules
Monitoring and Managing BBU Units with the MegaRAID Configuration Utilities
3.1.3.3
Display BBU Capacity
Use the command in the following table to display the BBU capacity for the selected controller or controllers.
For iBBU:
Relative State of Charge: xx
Charger System State: xx
Charger System Ctrl: xx
Charging Current: xx mA
Absolute State of Charge: xx%
Max Error: xx%
For BBU:
Relative State of Charge: xx
Charger Status: xx
Remaining Capacity: xx mAh
Full Charge Capacity: mAh
isSOHGood: Yes/No
Table 6 Display BBU Capacity Information
Convention
MegaCLI -AdpBbuCmd -GetBbuCapacityInfo –aN|-a0,1,2|-aALL
Description
Displays BBU capacity information. The information displays in the following format:
BBU Capacity Info for Controller: x
Relative State of Charge: xx%
Absolute State of Charge: xx%
Remaining Capacity: xx mAh
Full Charge Capacity: xx mAh
Run Time to Empty: xxx Hr yy Min
Average Time to Empty: xx Hr yy Min
Extimated Time to Full Recharge: XXXX(string)
Cycle Count: xx
Table 5 Display BBU Status Information (Continued)