1 removing the raid controller from the computer – Avago Technologies Cache Protection for RAID Controller Cards User Manual
Page 97

Avago Technologies
- 97 -
Cache Backup Products for MegaRAID SAS+SATA RAID Controllers User Guide
May 2015
Chapter 2: Installing the Cache Backup Products
Attaching the CVFM03 Module to a MegaRAID SAS 9265CV-8i RAID Controller and
Connecting to a Remote CVPM02 Module
2.10.2
Installing the CVFM03 Module Directly on the MegaRAID SAS 9265CV-8i RAID Controller
Follow these steps to install the CVFM03 module directly on the LSIiBB05.
1.
Remove the RAID controller from the computer. For this procedure, see
Section 2.10.2.1, Removing the RAID
2.
Attach the CVFM03 module directly to the RAID controller. For this procedure, see
Section 2.10.2.2, Attaching the
CVFM03 Module Directly to the RAID Controller
.
CAUTION
Electrostatic discharge can damage the CVFM03 module and the
MegaRAID SAS 9265CV-8i RAID controller. Make sure that you install
the CVFM03 module at an ESD-safe workstation that meets the
EIA-625 Standard. When you install the CVFM03 module, follow the
ESD-recommended practices in the latest revision of the IPC-A-610
(Acceptability of Electronic Assemblies) standard.
2.10.2.1
Removing the RAID Controller from the Computer
Follow these steps to remove the RAID controller from the computer.
1.
Turn off the power, and unplug the power cords.
2.
Ground yourself, and make sure that the system is grounded.
3.
Remove the cover from the computer according to the instructions in the system user’s manual to allow access to
the controller.
4.
Unplug all cables from the controller, remove the screw that attaches the bracket to the computer chassis, and
carefully remove the controller from the slot.
5.
Place the controller on a flat, clean, static-free surface, and continue with the next procedure.