5 monitoring cachevault module information – Avago Technologies Cache Protection for RAID Controller Cards User Manual
Page 131
Avago Technologies
- 131 -
Cache Backup Products for MegaRAID SAS+SATA RAID Controllers User Guide
May 2015
Chapter 3: Monitoring and Managing Battery Backup Units and CacheVault Modules
Monitoring CacheVault Module Information
3.5
Monitoring CacheVault Module Information
You can view information about the CVPM modules by using the following Avago software utilities:
HII Configuration Utility
StorCLI
3.5.1
Monitoring CacheVault Module Information with the HII Utility
You can use the HII Configuration utility to display information about the CVPM module on the following Battery
Management screen.
Figure 88 HII Battery Management
3.5.2
Monitoring CacheVault Module Information in StorCLI
The StorCLI software utility supports the following CacheVault command, which identifies the specific controller to
which a CacheVault module is connected:
storcli /cx/cv show all
The object identifier /cx/cv refers to the CacheVault module on controller x. Only one CacheVault module can be
connected to a controller at a time.
NOTE
This command works only when a CacheVault module is connected to
the controller; otherwise, an error message appears.
Input example:
storcli /c0/cv show all
c0
identifies controller number 0.